– 57 –
Both indoor units
start operation.
Unnecessary set
[Remote controller select]
Push the operation button
on the remote controller.
YES
NO
CLOCK
CHECK
RESET
CLR
SET
SWING
FIX
FAN
ON
OFF
HiPOWER
SLEEP MODE
MEMO
OFF
1.3.5.9H
When switching between settings “A” and
“B”, always switch the indoor unit board
and the remote controller as a pair.
(Otherwise, the indoor unit will not accept
the remote controller’s signals.)
Cutting direction
Jumper wire
Select “B” as the setting for
one of the two indoor units and
for the remote controller.
(See below for details.)
Item
17. Select switch on
remote controller
Operation flow and applicable data, etc.
Description
1. Purpose
This operation is to operate only one
indoor unit using one remote controller.
2. Description
When operating one indoor unit in a
situation where two indoor units have
been installed in the same room or
nearby rooms, this operation prevents the
remote controller signal from being
received simultaneously by both units,
thus preventing both units from operating.
3. Operation
The indoor unit on which the remote
controller selection has been set to B
receives the signal of the remote control-
ler also set to B.
(At the factory the remote controller
selection is set to A on all the indoor
units. There is no A setting display.)
1. Setting the remote controller
Slide and open the remote controller cover and remove the
batteries.
Cut the jumper wire inside the battery compartment using
nippers.
• The jumper wire should not remain in contact after being
cut. Also be careful not to let plastic scraps, jumper wire
cuttings or other debris enter the inside of the remote
controller.
Insert the batteries. “B” appears in the remote controller
display.
* Even after the jumper wire has been cut, switching
between A and B is still possible by pushing the CHECK
button and FIX button together.
The A or B setting, which was switched by pushing the
CHECK button and FIX button together, is restored to the
setting established prior to the switching when the battery
is replaced or the RESET button is pushed.
2. Setting the unit
Push the RESET button (Indoor unit) to start automatic
operation.
3. Push the
button of the remote controller that was set
in step 1 to stop the air conditioner.
(This operation will change the setting to “B”.)
4. Check that the remote controller operates the indoor unit.