6. SPECIFICATIONS OF ELECTRICAL PARTS
6-
1
.
Outdoor Unit
RAS-
4
M
27
S3AV-E, -A, -TR
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Parts name
Compressor
Outdoor fan motor
Reactor
Reactor
4-way valve coil
PMV coil
P.C. board (Main PCB)
P.C. board (Control PCB)
P.C. board (Fan motor connection)
Fuse (Mounted on P.C. board MCC-1571)
Fuse (Mounted on P.C. board MCC-1571)
Fuse (Mounted on P.C. board MCC-1571, MCC-5071)
Outdoor temp. sensor (TO sensor)
Evaporator temp. sensor (Te sensor)
Discharge temp. sensor (Td sensor)
Suction temp. sensor (Ts sensor)
Temp. sensor at A room gas side (TGa-sensor)
Temp. sensor at B room gas side (TGb-sensor)
Temp. sensor at C room gas side (TGc-sensor)
Temp. sensor at D room gas side (TGd-sensor)
Compressor thermo.
Terminal block (9P)
Model name
DA2
2
0A2
T
-20L
D
IC
F-
28
0-A
6
0
-1
CH-56-3Z-T
CH-76-TM1
5TF-H01AP1874A1
UKV-A
039
MCC-1571
MCC-5071
MCC-1436
—
—
—
—
—
—
—
—
—
—
—
CS-12AL
—
Rating
—
Output
6
0 W
5.8 mH, 18.5 A
9.9 mH, 1 A
AC 200–240 V
DC 12 V
AC 220–240 V
AC 220–240 V
AC 220–240V
AC 250V, 25 A
AC 250V, 10 A
AC 250V, 3.15 A
10 k
Ω
(25°C)
10 k
Ω
(25°C)
50 k
Ω
(25°C)
10 k
Ω
(25°C)
10 k
Ω
(25°C)
10 k
Ω
(25°C)
10 k
Ω
(25°C)
10 k
Ω
(25°C)
ON: 90°C, OFF: 125°C
AC 250 V, 20 A
FILE NO. SVM-15073
- 40 -