Reactor cover side
Inverter box side
Inverter box side
Inverter box side
Soundproof plate (upper)
Hook
Compressor lead
Case thermo
White
Red
Partition cover
Black
Black
Black
No.
4
Part name
Inverter
assembly
(Continued)
Procedure
8) Remove the soundproof plate (upper).
9) Remove the terminal cover of the compressor
and then remove the compressor lead of the
compressor.
10) Pull up the inverter assembly and then remove it.
∗
Hold up both the reactor cover side and the
inverter box side and then remove the inverter
assembly upward.
∗
Caution to mount the inverter assembly
When mounting the inverter assembly to the
partition plate, be sure to do hooking.
NOTE)
Using the bundling band on the market, be sure
to bind the portions which were bound before.
Remarks
FILE NO. SVM-15073