9-
3
. Service switch (SW
8
01, SW
8
02) operations
Various displays and various operations are enabled by push buttons (service) switches and LED on the
outdoor control P.C. board.
9-
3
-1. LED display
5 patterns are provided for LED display.
○:ON (○*:3 sec ON/0.5 sec OFF), ●:OFF, ◎:Rapid Flashing(5 times/sec), ◇:Slow Flashing(1 time/sec)
When the initial status does not appear (in case of flashing of D804 or D805), LED display can be returned to
the initial status by pushing and holding the service switches SW
8
01 and SW
8
02 for 5 seconds or more
simultaneously.
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
●/○
(*)
/◎ ●/○
(*)
/◎ ●/○
(*)
/◎ ●/○
(*)
/◎
●/○
(*)
/◎/◇
●/○/◎/◇
In the initial status of LED display, D805 is ON as below.
Normal
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
●
●
●
●
●
○
○:ON ●:OFF
Error occurring
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
●/○*
●/○*
●/○*
●/○*
●/○*
○
○:ON ○*:3 sec ON/0.5 sec OFF ●:OFF
FILE NO. SVM-18052
- 50 -