– 136 –
4
Inverter
assembly
(Continued)
8) Remove the soundproof plate (upper).
9) Remove the terminal cover of the compressor and then
remove the compressor lead of the compressor.
10) Pull up the inverter assembly and then remove it.
∗
Hold up both the reactor cover side and the inverter box
side and then remove the inverter assembly upward.
∗
Caution to mount the inverter assembly When mounting
the inverter assembly to the partition plate, be sure to do
hooking.
NOTE
Using the bundling band on the market, be sure to bind the
portions which were bound before.
No. Part name
Procedure
Remarks
Reactor cover side
Inverter box side
Inverter box side
Inverter box side
Hook
Partition cover
Soundproof plate (upper)
Compressor lead
Case thermo
White
Red
Black
Black
Black