– 57 –
1. Basic
operation
(Continued)
2. Operating mode selection when performing 2-room operation
1) The outdoor unit operating mode conforms to the instructions of the indoor unit that was pushed first.
2) When combined operation consisting of cooling (dry) and heating, fan (air purification) and heating, or
cleaning operation and heating is performed, operation conforms to the instructions of the indoor unit
that was pushed first as shown in the following table.
3) The indoor fan stops for the indoor unit that was pushed last and which instructions are ignored.
4) When three or four indoor units are operated concurrently, the priority is also given to operating mode
of the indoor unit which was pushed first as same as the case when two indoor units are operated
concurrently.
3. Cooling / Heating operation
The operations are performed in the following parts by controls according to cooling / heating conditions.
1) Receiving the operation ON signal of the remote controller, the cooling or heating operation signal starts
being transferred from the indoor controller to the outdoor unit.
2) At the indoor unit side, the indoor fan is operated according to the contents of “
2. Indoor fan motor
control
” and the louver according to the contents of “
10. Louver control
”, respectively.
3) The outdoor unit controls the outdoor fan motor, compressor, pulse motor valve (PMV) and 4-way valve
according to the operation signal sent from the indoor unit.
∗
1. The relay of 4-way valve is turned on, for a few seconds when 4-way valve is driven.
Item
Operation flow and applicable data, etc.
Description
No.
Indoor unit
Set operating mode
Actual indoor unit operation
Actual outdoor unit operation
1
Pushed first
Cooling (dry)
Cooling (dry)
Cooling
Pushed last
Cooling (dry)
Cooling (dry)
2
Pushed first
Heating
Heating
Heating
Pushed last
Heating
Heating
3
Pushed first
Fan (solo air purification)
Fan (solo air purification)
Stopped
Pushed last
Fan (solo air purification)
Fan (solo air purification)
4
Pushed first
Fan (solo air purification)
Fan (solo air purification)
Cooling
Pushed last
Cooling (dry)
Cooling (dry)
5
Pushed first
Cooling (dry)
Cooling (dry)
Cooling
Pushed last
Fan (solo air purification)
Fan (solo air purification)
6
Pushed first
Cooling (dry)
Cooling (dry)
Cooling
Pushed last
Heating
Fan stopped
7
Pushed first
Heating
Heating
Heating
Pushed last
Cooling (dry)
Fan stopped
8
Pushed first
Fan (solo air purification)
Fan (solo air purification)
Stopped
Pushed last
Heating
Fan stopped
9
Pushed first
Heating
Heating
Heating
Pushed last
Fan (solo air purification)
Fan stopped
10
Pushed first
Cleaning operation
Cleaning operation
Stopped
Pushed last
Cleaning operation
Cleaning operation
11
Pushed first
Cleaning operation
Cleaning operation
Cooling
Pushed last
Cooling (dry)
Cooling (dry)
12
Pushed first
Cooling (dry)
Cooling (dry)
Cooling
Pushed last
Cleaning operation
Cleaning operation
13
Pushed first
Cleaning operation
Cleaning operation
Stopped
Pushed last
Fan (solo air purification)
Fan (solo air purification)
14
Pushed first
Fan (solo air purification)
Fan (solo air purification)
Stopped
Pushed last
Cleaning operation
Cleaning operation
15
Pushed first
Cleaning operation
Cleaning operation
Stopped
Pushed last
Heating
Fan stopped
16
Pushed first
Heating
Heating
Heating
Pushed last
Cleaning operation
Cleaning operation
Operation ON
Setup of remote controller
Indoor fan motor control / Louver control
Compressor revolution control / Outdoor fan motor control / 4-way valve control
Pulse motor valve control
Indoor unit control
Sending of operation command signal
Outdoor unit control