6-1. Indoor Unit
6-2. Outdoor Unit
No.
Type name
Specifications
1
Compressor
RAS-05, 07
NX66F0F-20D
3-Phases (6-Poles) ; 630W
RAS-10, 13
KSK89D53UEZ
3-Phases (6-Poles) ; 7
12
W
RAS-16
KSN108D22UFZ
3-Phases (6-Poles) ; 840W
2
Fan Motor
WDF-340-A43-1
DC 140-340V ; 43W
3
Pulse Modulating Valve (PMV) coil
PQ-M10012-000313
DC 12V
4
4-Way valve coil
DXQ-939
AC 220-240V
5
Reactor
RAS-16
CH-69-Z-T
L = 19mH, 10A
6
Suction temp. sensor
(TS sensor)
(Inverter attached)
10kΩ at 25°C
7
Discharge temp. sensor
(TD sensor)
(Inverter attached)
62kΩ at 20°C
8
Outside air temp. sensor
(TO sensor)
(Inverter attached)
9
Heat Exchanger temp. sensor
(TE sensor)
(Inverter attached)
10kΩ at 25°C
10 Terminal block
(5 poles)
JXO-5B
AC 250V, 20A
Parts name
10kΩ at 25°C
No.
Type
ype
Specificat
1
Fan Motor (for indoor)
RAS-B05, 07, 10, 13
SJM-240-25
AC 220~240V, 25W
RAS-
B
1
6
SJM-240-35
AC 220~240V, 35W
2
Room temp. sensor (TA-sensor)
(-)
10k
Ω
at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
(-)
10k
Ω
at 25°C
4
Heat exchanger temp. sensor (TCJ-sensor)
(-)
Parts name
5
Louver motor
24BYJ48
A
-
080
Output (Rated) 4 phase, DC12V
10k
Ω
at 25°C
6. SPECIFICATIONS OF ELECTRICAL PARTS
RAS-
05, 07,16
RAS-
10,13
ICF-140-43-4
R
DC 140-340V ; 43W
FILE NO. SVM-18006
- 23 -
FILE NO. SVM-18006
- 23 -