– 113 –
Valve
fixing
plate
Compressor
Partition
board
Reactors
No.
7
8
Part name
Compressor
Reactor
Procedure
1) Perform work of item 1 of
1
and
2
,
3
,
4
,
5
.
2) Extract refrigerant gas.
3) Remove the partition board.
(ST1TØ4 × 8L 3 pcs.)
4) Remove the sound-insulation material.
5) Remove terminal cover of the compressor,
and disconnect lead wire of the compres-
sor and the comp. thermo. assembly from
the terminal.
6) Remove pipe connected to the compres-
sor with a burner.
• Take care to keep the 4-way valve away
from naked flames.
(Otherwise, it may malfunction.)
7) Remove the fixing screw of the bottom plate
and heat exchanger. (ST1TØ4 × 8L 1 pc.)
8) Remove the fixing screw of the bottom
plate and valve fixing plate.
(ST1TØ4 × 8L 1 pc.)
9) Pull upward the refrigeration cycle.
10) Remove BOLT (3 pcs.) fixing the com-
pressor to the bottom plate.
∗
Precautions when assembling the
compressor.
Tighten the compressor bolts using a
tightening torque of 4.9 N•m.
1) Perform work of item 1 of
2
, and
3
.
2) Remove screws fixing the reactor.
(ST1TØ4 × 8L 4 pcs.)
Remarks