– 43 –
Indoor unit A
Inverter
Outdoor unit
Compressor
Indoor unit B
Outdoor temp. To
Setup of current release point
Capacity control continues.
Outdoor temp.
40˚C
7.5A
12.0A
10.1A
10.3A
10.5A
16˚C
39˚C
11˚C
15.5˚C
10.5˚C
Cooling current
release value
Heating current
release value
Current decrease
Outdoor unit inverter main
circuit control current
High
Low
Reduce compressor speed
Operating current
≤
Setup value
Item
4. Capacity control
5. Current release
control
Operation flow and applicable data, etc.
This function prevents troubles on the electronic parts of the
compressor driving inverter.
This function also controls drive circuit of the compressor
speed so that electric power of the compressor drive circuit
does not exceed the specified value.
Description
1) Indoor unit A and Indoor unit B
determine the respective
instruction revolutions from the
difference between the remote
controller setting temperature
(Ts) and the indoor temperature
(Ta), and transmit this to the
outdoor unit.
2) The outdoor unit receives the
instructions from the indoor units,
and the inverter operates the
compressor at the calculated
revolutions.
3) The compressor operation range
in each operating mode is shown
in the left table.
1) The input current of the outdoor
unit is detected in the inverter
section of the outdoor unit.
2) According to the detected
outdoor temperature, the
specified value of the current is
selected.
3) Whether the current value
exceeds the specified value or
not is judged.
4) If the current value exceeds the
specified value, this function
reduces the compressor speed
and controls speed up to the
closest one commanded from the
indoor unit within the range which
does not exceed the specified
value.
Outdoor
unit
M18GAV-E
M18GACV-E
M18GAV-E
M14GAV-E
M14GACV-E
M14GAV-E
Operation
mode
Cooling
Heating
Cooling
Heating
No.of
operating unit
1 unit
2 units
1 unit
2 units
1 unit
2 units
1 unit
2 units
Combination
of indoor units
10
—
13
—
16
—
10
10
13
10
13
13
16
10
10
—
13
—
16
—
10
10
13
10
13
13
16
10
10
—
13
—
10
10
13
10
10
—
13
—
10
10
13
10
Compressor
revolution (rps)
13 to 045
13 to 071
13 to 079
15 to 083
15 to 083
15 to 083
15 to 083
13 to 076
13 to 099
13 to 102
15 to 120
15 to 120
15 to 120
15 to 120
13 to 056
13 to 074
18 to 074
18 to 075
13 to 075
13 to 080
16 to 084
16 to 085