– 48 –
Filter lamp ON
Press RESET button.
Did you press [RESET] button
for 3 seconds or more?
Did you press [RESET] button
for 10 seconds or more?
Switch to [AUTO RESTART] control.
YES
YES
NO
NO
NO
YES
Temporary [AUTO] operation
Temporary [COOL] Operation
Sending air purifier-ON
Operation lamp ON
Fan ON
Air purifier ON
Air purifying operation
Start of air purifier-ON
Operation lamp OFF
Filter-OFF
Memory position
of louver/COOL
Air condi
air purifier operate
Fan stop
Air purifier-OFF
Louver close
All stop
Air conditioner operates
Sending air purifier-OFF
1
,
2
3
1
2
3
4
,
4
Air conditioner operates
Air conditioner stops
Air purifier operates
Air condi
Air purifier operate
*1
*2
Item
11. Temporary
operation
Operation flow and applicable data, etc.
Pressing [RESET] button starts the temporary
operation of [AUTO] operation. When keeping [RE-
SET] button pressed for 10 seconds or more, the
temporary [COOL] operation is performed.
12. Air purifying
control
This function generates nagative ion while cleaning the air in the room.
If air purifier-ON signal is received while the air conditioner stops, the air purifier starts operation, and
if it is received while the air conditioner operates, the air conditioner and the air purifier start operation.
The air ion generator operates linked with the air purifying operation.
Description
1) When pressing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pressed
for 3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pressed
for 10 seconds or more, “Pi” sound is
heard and the temporary [COOL] opera-
tion starts.
4) If the filter lamp goes on, press [RESET]
button to go off the filter lamp, and then
press [RESET] button again.
5) To stop the temporary operation, press
the button again.
∗
When the previous operation was the
operation of air condi air purifier,
an operation of air condi air purifier
starts by pushing AC button on the remote
controller.
(Operation of air condi air purifier is
stored in memory.)
∗
1 Swing is available
∗
2 Fan speed is Fan Auto mode varies in
order, (M + 1)
→
(L)
→
(L–)
→
(SL).
Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Operation button
PURE button
Air conditioner
Air purifier
AC operation*
Stop (All)
AC + Air purifier
AC + Air purifier
All stop
AC operation
All stop
Air purifying operation
AC + Air purifying operation
Louver
∗
1
Cooling position
Follows to AC operation
Fan speed
∗
2
AUTO, L, L+, M, M+, H
Follows to AC operation