6-1. Indoor Unit
6-2. Outdoor Unit
No.
Parts name
Type
Specifications
AFN-220-20-4D
AC 240V, 20W
2 Room temp. sensor (TA-sensor)
( - )
10k
Ω
at 25
°
C
3 Heat exchanger temp. sensor (TC-sensor)
( - )
10k
Ω
at 25°C
4
Louver motor
MSBPC20F04
Output (Rated) 1W, 16 poles, DC12V
No.
Parts name
Type
Specifications
L = 19mH, 10A
2
Outdoor fan motor
ICF-140-43-4R
DC140V, 43W
3 Suction temp. sensor (TS sensor)
(Inverter attached) 10k
Ω
(25°C)
4 Discharge temp. sensor (TD sensor)
(Inverter attached) 62k
Ω
(20°C)
5 Outside air temp. sensor (TO sensor)
(Inverter attached) 10k
Ω
(25°C)
6 Heat exchanger temp. sensor (TE sensor)
(Inverter attached)
10k
Ω
(25°C)
Reactor
1
1
Fan motor (for indoor)
20A, AC250V
DA89X1C-23FZ2
CAM-MD12TCTH-5
STF-01AJ646A1
3-phases 4-poles 750W
DC12V
AC220-240V
Coil for 4-way valve
Coil for PMV
Compressor
Terminal block (5P)
7
8
9
10
CH-69 (1 PC)
6. SPECIFICATIONS OF ELECTRICAL PARTS
FILE NO. SVM-12050
–
18
–
JX0-5B