7-2. Operation Data
<Cooling>
Tempeature
Model name
Standard
Heat exchanger
Indoor
Outdoor
Compressor
condition(°C)
RAS-
pressure
pipe temp.
fan mode
fan mode
revolution
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
(rps)
27/19 35/- B10N3KVP-E 0.9 to 1.1 12 to 14 40 to 42 High High 37
B13N3KVP-E 0.8 to 1.0 8 to 10 41 to 43 High High 59
B16N3KVP-E 0.7 to 0.9 7 to 9 42 to 44 High High 83
<Heating>
Tempeature
Model name
Standard
Heat exchanger
Indoor
Outdoor
Compressor
condition(°C)
RAS-
pressure
pipe temp.
fan mode
fan mode
revolution
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
(rps)
20/- 7/6 B10N3KVP-E 2.5 to 2.7 36 to 38 2 to 3 High High 48
B13N3KVP-E 2.7 to 2.9 40 to 42 2 to 3 High High 65
B16N3KVP-E 2.9 to 3.1 49 to 51 1 to 2 High High 83
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchaner path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m