Packed Valve handling precautions
CAUTION
• Wrongt wiring connection may cause electrical
parts to burn out.
• Be sure to comply with local cords on running
the wire from indoor unit to outdoor unit
(size of wire and wiring method, etc.)
•
Every wire must be connected firmly.
• This installation fuse (15A) must be used for
the power supply line of this air conditioner.
•
If incorrect or incomplete wiring is carried out,
it will cause an ignition or smoke.
•
Prepare the power supply for exclusive use
with the air conditioner.
•
This product can be connected to the mains.
Connection to fixed wiring:
A switch which disconnects all poles and has a
contact separation of at least 3 mm must be
incorporated in the fixed wiring.
Connecting cable
Power cord
0
1
0
1
0
1
0
1
30
30
40
40
L N
1 2 3
Earth line
Earth line
Power source
50Hz, 220 - 240V / 60Hz, 220
Maximum
running current
Plug socket &
15A
fuse rating
Power cord
H07RN-F or 245 IEC66 (1.5 mm
2
or more)
11A
Stripping length of connecting cable
1
2
3
L
N
Terminal block
Connecting cable
Power cord
NOTE : Connecting cable
•
Wire type : More than H07RN-F or 245 IEC66
(1.0 mm
2
or more.)
Fig. 10-4-11
10-4-5. Wiring connection
1. Remove the valv
Fig. 10-4-10
e cover from the outdoor unit.
2. Connect the connecting cable to the terminals
as identified with their respective matched numbers
on the terminal block of indoor and outdoor unit.
3. When connecting the connecting cable to the outdoor
unit terminals, make a loop as shown in the installation
diagram of indoor and outdoor unit to prevent water
•
Open the valve stem all the way out, but do not try
to open it beyond the stopper.
coming in the outdoor unit.
Cap
4. Insulate the unused cords (conductors) from any
Torque
A
H
Hexagon wrench
is required.
Service Port Cap
Valve Rod Cap
Pipe size of Packed Valve
Size of Hexagon wrench
CAUTION
12.70 mm and smallers
A = 4 mm
15.88 mm
A = 5 mm
•
water coming in the outdoor unit. Proceed them so
Securely tighten the valve cap with torque in the
that they do not touch any electrical or metal parts.
following table
Cap Size (H)
Valve Rod
Cap
Service
Port Cap
H17 - H19
H22 - H30
H14
H17
14~18 N.m
(1.4 to 1.8 kgf·m)
33~42 N.m
(3.3 to 4.2 kgf·m)
8~12 N.m
(0.8 to 1.2 kgf·m)
14~18 N.m
(1.4 to 1.8 kgf·m)
FILE NO. SVM-12051
Single phase