FILE NO. SVM-12051
No.
Part name
Front panel
Procedures
4) Press "PUSH" part under the front panel
and remove hooks of the front panel from
the installation plate.
Remarks
Press
Front panel
Installation plate
5) Remove the front panel fixing screws.
(2 pcs.)
6) Take off three hooks of panel from rear
side.
2 Screws
Three hooks
<How to assemble the front panel>
1) Press three center positions and two low
Holder
Plasma air purifier
Protrusion
er center positions of the air outlet, and
then hang the hanging hooks (3 pcs.) at the top side of the front panel to the rear
plate.
2) Insert the plasma air purifier
H
older
Protrusion
Plasma air purifier
Press in the plasma air parifier until the protrusions on both sides are completely
inserted into the holders.
If installation is incomplete, the FILTER indicator (orange) may light.
3) Tighten two screws.
• Incomplete hanging or incomplete pressing may cause a dewdrops or generation
of a fluttering sound.