FILE NO. SVM-12051
–
91
–
No.
Part name
High voltage
generator
Procedures
1) Follow to the procedure in the item
.
2) To remove the air ionizer from the back body,
pull it toward you.
Remarks
2) Secure it using the fixing screws. (2 pcs)
3) Connect the connectors of the high-voltage
generat
4) Attach the air ionizer to the back body.
<How to assemble the high voltage generator>
1) Insert the high voltage generator straight into
the evaporator
voltage generator from the evaporator.
Check whether it is
c
ompleted inserted.
3) Disconnect the connectors of the high voltage
generator.
4) Remove the fixing screws (2 pcs) and remove
the high voltage generator from the evaporator.
Connector
2 Screws