– 25 –
Item
Operation flow and applicable data, etc.
Description
2. Indoor fan
motor
control
1) Operation with (HH), (H+), (H), (L+), (L) or [AUTO] mode is carried
out by the command from the remote controller.
2) When the air speed mode [AUTO] is selected, the air speed varies
by the difference between Ta and Ts.
• Controlling operation in case when thermo of remote controller works
is same as a case when thermo of the body works.
• If the air speed has been changed once, it is not changed for
3 minutes. However when the air volume is exchanged, the air speed
changes.
• When cooling operation has started, select a downward slope for the
air speed, that is, the high position.
• If the temperature is just on the difference boundary, the air speed
does not change.
• Mode in the parentheses indicates one in automatic cooling
operation.
Value in the parentheses indicates one when thermostat of the remote
controller works.
Value without parentheses indicates one when thermostat of the body
works.
• If the air speed has been changed once, it is not changed for 1
minute. However when the air speed is exchanged, the air speed
changes.
• When heating operation has started, select an upward slope for the
air speed, that is, the high position.
• If the temperature is just on the difference boundary, the air speed
does not change.
• Mode in the parentheses indicates one in automatic heating
operation.
• In Tc
≥
60°C, the air speed increases by 1 step.
HH > H+ > H > L+ > L > UL
Tc: Indoor heat
exchanger sensor
temperature
Ta (˚C)
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
Tsc
–0.5
HH
(HH)
H+ (HH)
H (HH)
L+ (H+)
L (H)
L (H)
L (L+)
D
C
B
A
E
F
G
<COOL>
Ta (˚C)
(–0.5) –1.0
Tsh
(+0.5) +1.0
(+1.0) +2.0
(+1.5) +3.0
(+2.0) +4.0
L (L+)
L+ (H)
H (H+)
HH
(HH)
H+
(HH)
E
D
C
B
A
<HEAT>