– 26 –
Item
Operation flow and applicable data, etc.
Description
2. Indoor fan
motor
control
3) In heating operation, the mode changes to [LL] if thermostat is
turned off.
4) If Ta
≥
25°C when heating operation has started and when defrost
operation has been cleared, the air conditioner operates with (H)
mode or higher mode for 1 minute after Tc entered in E zone of cool
air discharge preventive control.
Tcj:
Indoor heat exchanger
sensor temperature
tap
COOL
HEAT
External static pressure selection
10Pa
20Pa
35Pa
45Pa
F1
HH
1020
1120
1200
1260
F2
HH
1020
1120
1200
1260
F3
H+
960
1020
1120
1160
F4
H+
960
1020
1120
1160
F5
H
880
940
1020
1040
F6
H
880
940
1020
1040
F7
L+
820
870
940
980
F8
L+
820
870
940
980
F9
L
740
780
850
890
FA
L
740
780
850
890
FB
730
730
770
820
FC
730
730
770
820
FD
LL
LL
610
610
610
610
Revolution speed of indoor fan (rpm)
■
M07G3DV, M10G3DV
tap
COOL
HEAT
External static pressure selection
10Pa
20Pa
35Pa
45Pa
F1
HH
1120
1160
1240
1300
F2
HH
1120
1160
1240
1300
F3
H+
1000
1040
1140
1200
F4
H+
1000
1040
1140
1200
F5
H
920
970
1040
1120
F6
H
920
970
1040
1120
F7
L+
830
870
930
980
F8
L+
830
870
930
980
F9
L
740
780
840
870
FA
L
740
780
840
870
FB
730
730
770
820
FC
730
730
770
820
FD
LL
LL
610
610
610
610
■
M13G3DV
tap
COOL
HEAT
External static pressure selection
10Pa
20Pa
35Pa
45Pa
F1
HH
1020
1120
1220
1260
F2
HH
1020
1120
1220
1260
F3
H+
960
970
1100
1140
F4
H+
960
970
1100
1140
F5
H
810
810
960
1020
F6
H
810
810
960
1020
F7
L+
730
750
810
960
F8
L+
720
750
810
960
F9
L
660
700
760
800
FA
L
630
670
720
760
FB
630
630
660
680
FC
630
630
640
660
FD
LL
LL
550
550
550
550
■
M16G3DV