– 34 –
Item
Operation flow and applicable data, etc.
Description
12. Self-Cleaning
function
1. Purpose
The Self-Cleaning operation is to minimize
the growth of mold, bacteria etc. by
running the fan and drying so as to keep
the inside of the air conditioner clean.
Self-Cleaning operation
When the cooling or dry operation shuts
down, the unit automatically starts the
Self-Cleaning operation which is then
performed for the specified period based
on duration of the operation which was
performed prior to the shutdown, after
which the Self-Cleaning operation stops.
(The Self-Cleaning operation is not
performed after a heating operation.)
2. Operation
1) When the stop signal from the remote
controller or timer-off function is
received, only the PRE.DEF indicator
light.
2) The period of the Self-Cleaning
operation is determined by the duration
of the operation performed prior to the
reception of the stop code.
3) After the Self-Cleaning operation has
been performed for the specified
period, the unit stops operating.
• During Self-Cleaning operations: The indoor fan
operates continuously at a speed of M07/10/13 :
610 rpm, M16 : 630 rpm.
Unit now performing cooling or dry operation
Press “STOP” button
Only PRE, DEF indicator lights, and Self Cleaning operation starts
Time set now elapses
Operation stops
Operation time
Self-Cleaning operation time
Cooling: Auto (cooling) Dry
Up to 10 minutes
No Self-Cleaning operation
performed (0 minutes)
10 minutes or longer
30 mins.
Heating: Auto (heating)
No Self-Cleaning operation performed
Auto (fan only)
Shutdown
• To stop an ongoing Self-Cleaning operation at any time
Press the start/stop button on the remote controller twice during the Self-Cleaning
operation. (After pressing the button for the first time, press it for the second time
without delay (within 10 minutes).)
Self-Cleaning operation times
Summary of Contents for ras-m07g3dv-e
Page 86: ... 85 13 EXPLODED VIEWS AND PARTS LIST 13 1 Indoor Unit ...
Page 93: ......