Table 6-1-2
NOTE :
• UL : Ultra Low, SUL : Super Ultra Low
6-1-6. Louver Control
(1) Vertical air flow louvers
Positions of vertical air flow louvers are automati-
cally controlled according to the operation status
(AUTO, COOL, DRY, HEAT). Besides, positions of
vertical air flow louvers can be arbitrarily set by
pressing the [FIX] button. The louver position which
has been set by the [FIX] button is stored in micro-
computer, and the louver is automatically set at the
stored position in the next operation.
(2) Swing
If the [SWING] button is pressed during running
operation, vertical air flow louvers start swinging.
When the [SWING] button is pressed again, swinging
stops.
6-1-7. Indoor Fan Control
The indoor fan is operated by motor speed non-step
variable drive system motor. For flow rate, motor
speed is controlled manually in five steps and with
the unit of 10 rpm from upper limit to lower limit in
AUTO mode as described in Table 6-1-2. It is not
selected by relay, so selecting sound does not
generate.
6-1-4. Prevent-Freezing Control
The indoor heat exchanger sensor detects refriger-
ant vapor temperature in COOL/DRY operation. If
the temperature is below the specified value, com-
pressor motor speed is reduced so that operation is
performed in temperature below the specified value
to prevent-freezing of indoor heat exchanger.
6-1-5. P. M. V. (Pulse Modulating Valve)
Using P.M.V., refrigerant flow of refrigeration cycle is
varied for the optimum temperature. Controlling
each unit separately by four P.M.V. corresponds to
difference of pipe length, fan speed, and unit tem-
perature.
If an error occurs on cycle temperature when power
source of the air conditioner has been turned on,
and if start/stop times of the outdoor unit are 30
times, move the valve once until it hits on the stopper
for positioning of the valve. In this case, ticktack
sound may be heard.
Remote
H
operation
mode
Cooling
and Fan
only
DRY
Heating
Fan
mode
M+
M
L+
L
L-
L+
L
L-
UL
SUL
H
M+
M
L+
L
L-
Control
HIGH
MED+
MED
LOW+
LOW
HIGH
MED+
MED
LOW+
LOW
M10
M13
M16
(rpm)
Motor speed Air flow rate
(m
3
/h)
Motor speed Air flow rate
(m
3
/h)
(rpm)
Motor speed Air flow rate
(m
3
/h)
(rpm)
1190
1120
1120
1050
980
930
910
570
530
530
490
440
420
410
850
370
1210
1130
1130
1050
980
930
590
530
530
490
440
420
410
850
370
910
1350
1250
1250
1150
1070
1000
650
610
610
550
500
460
440
920
410
980
930
910
850
720
660
420
410
370
290
260
930
910
850
750
700
420
410
370
310
280
1000
980
920
920
800
460
440
410
410
340
1250
1200
1160
1060
1000
1050
940
610
570
550
490
460
490
420
930
420
1290
1280
1200
1100
1020
1050
620
620
570
520
470
490
420
930
420
940
1370
1360
1280
1180
1100
1150
660
660
620
560
520
550
470
1000 460
1020
FILE NO. SVM-05019
−
10
−