– 40 –
Item
Operation
fl
ow and applicable data, etc.
Description
11. Temporary
operation
Pushing [RESET] button starts the temporary
operation of [AUTO] operation. When keeping
[RESET] button pushed for 10 seconds or more, the
temporary [COOL] operation is performed.
1) When pushing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pushed for 3
seconds or more, “beep, beep, beep” sound
is heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pushed for
10 seconds or more, “beep” sound is heard
and the temporary [COOL] operation starts.
4) If the
fi
lter lamp goes on, push [RESET]
button to go off the
fi
lter lamp, and then
push [RESET] button again.
5) To stop the temporary operation, push the
button again.
PURE indicator (Orange) ON
Push RESET button.
Did you push [RESET] button
for 3 seconds or more?
Did you push [RESET] button
for 10 seconds or more?
Switch to [AUTO RESTART] control.
YES
YES
NO
NO
NO
YES
Temporary [AUTO] operation
Temporary [COOL] Operation
12. Air purifying control
1. Purpose
This function generates negative ion while
cleaning the air in the room.
The air purifying control function is to alert
the user that something is wrong in the
ionizing or air purifying operation.
If air puri
fi
er-ON signal is received while the
air conditioner stops, the air puri
fi
er starts
operation, and if it is received while the air
conditioner operates, the air conditioner
and the air puri
fi
er start operation.
The air ion generator operates linked with
the air purifying operation.
Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Operation button
PURE button
Air conditioner
Air purifier
AC operation*
Stop (All)
AC + Air purifier
AC + Air purifier
All stop
AC operation
All stop
Air purifying operation
AC + Air purifying operation
Louver swing is available
Cooling position
Follows to AC operation
Fan speed
1
AUTO, L, L+, M, M+, H
Follows to AC operation
NOTE
When the previous operation was the operation of air condi air puri
fi
er, an operation of air condi air
puri
fi
er starts by pushing AC button on the remote controller. (Operation of air condi air puri
fi
er is stored in
memory.)
0
8
15
30
min
Sending air purifier-ON
Sending air purifier-OFF
[1], [2]
[3], [4]
[1] Air conditioner stops
[2] Air conditioner
operates
[3] Air purifier operates
[4] Air condi
Air Purifier operation
Operation indicator ON
PURE indicator ON
Operation indicator OFF
PURE indicator OFF
PURE indicator ON
Moving panel Open
Fan ON
Air purifier ON
Air purifier ON
PURE indicator OFF
Air purifier OFF
1
Louver Open memory
position (Cooling)
Fan OFF
Air purifier OFF
Louver close
All stop
WC (WF)
W7 (WA)
W5 (W7)
W2 (W3)
Fan speed level
( )
: Hi Power
Air conditioner operates
Air purifying operation
Air condi
air purifier operation
1 Fan speed at Fan Auto mode.