– 44 –
Item
Operation
fl
ow and applicable data, etc.
Description
16. Clean operation
cancel
Setting the clean operation cancel
Add J231 of the wireless unit P.C. board assembly.
This cancels the auto restart function.
Hold down the [RESET] button on the indoor unit for
at least 3 seconds but not more than 10 seconds.
The indoor unit’s buzzer emits three beeps.
This completes the clean operation cancel setting.
Setting the clean operation
Hold down the [RESET] button on the indoor unit for
at least 3 seconds but not more than 10 seconds.
The indoor unit’s buzzer emits three beeps, and
the OPERATION indicator flashes at 5 Hz intervals.
This completes the clean operation setting.
Indoor P.C. board
CAUTION
∗
J231 will be near the MCU so take
steps to ensure that it will not be
exposed to excessive levels of
heat.
Also take care to avoid solder
bridging with the surrounding
components.
NOTE
Once J231 is added, the [RESET]
button on the unit is designated for
CLEAN OPERATION (Set/Cancel),
therefore the [RESET] button
cannot be used for the selection
(Set/ Cancel) of AUTO RESTART
function (Refer to
9-3. Auto Restart
Function
).
J231
IC231
J231
MCC-5068B