Heat insulator

Drain hose

Piping and Drain Hose Installation

*  Since dewing results in a machine trouble, make sure to insulate both 

connecting pipes. (Use polyethylene foam as insulating material.)

     

Piping and drain hose forming

How to remove the drain cap

Clip the drain cap by needle-nose 
pliers and pull out.

How to remove the drain hose

•  The drain hose can be removed by removing the 

screw securing the drain hose and then pulling out 
the drain hose.

•  When removing the drain hose, be careful of any 

sharp edges of steel plate. The edges can injuries.

•  To install the drain hose, insert the drain hose 

fi

 rmly until the connection part contacts with heat 

insulator, and then secure it with original screw.

How to 

fi

 x the drain cap

1)  Insert hexagon wrench (4 mm) 
  in a center head.

2)  Firmly insert the drain cap.

Firmly insert the drain hose and drain cap; otherwise, water may leak.

In case of right or left piping

•  Take off the cap by hand and cut of the slit.
•  After scribing slits of the bush body with a knife or a making-off pin, cut 

them with a pair of nippers or an equivalent tool. 

In case of bottom right or bottom left piping

•  After scribing slits of the bush body with a 

knife or a making-off pin, cut them with a 
pair of nippers or an equivalent tool. 

Left-hand connection with piping

• Bend the connecting pipe so that it is laid within 43 mm above the wall 

surface. If the connecting pipe is laid exceeding 43 mm above the wall 
surface, the indoor unit may unstably be set on the wall.

  When bending the connecting pipe, make sure to use a spring bender so as 

not to crush the pipe.

Bend the connecting pipe within a radius of 30 mm.

To connect the pipe after installation of the unit (

fi

 gure)

CAUTION

 

326 mm

283 mm

43 mm

80°

Liquid side

Gas side

(To the forefront of 

fl

 are)

Outward form of indoor unit

R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)

Use the handle of screwdriver, etc.

Slit

Cap

Slit

 

NOTE

If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.
After passing the connecting pipe through the pipe hole, connect the 
connecting pipes to the auxiliary pipes and wrap the facing tape around 
them.

• Bind the auxiliary pipes (two) and connecting cable with facing tape 

tightly. In case of leftward piping and rear-leftward piping, bind the 
auxiliary pipes (two) only with facing tape.

 

Indoor unit

Connecting cable

Auxiliary pipes

Installation plate

•  Carefully arrange pipes so that any pipe does not stick out of the rear 

plate of the indoor unit.

• Carefully connect the auxiliary pipes and connecting pipes to one 

another and cut off the insulating tape wound on the connecting pipe 
to avoid double-taping at the joint; moreover, seal the joint with the 
vinyl tape, etc.

•  Since dewing results in a machine trouble, make sure to insulate both 

connecting pipes. (Use polyethylene foam as insulating material.)

•  When bending a pipe, carefully do it, not to crush it. 

CAUTION

1.  Die-cutting bush body slit

 

•  For Bottom left or Bottom right

    Cut out the slit on bottom left or right side of bush body for the bottom left 

or right connection with a pair of nippers.

 

•  For Left or Right

Take off Cap and cut out the slit on left or right side of bush body for the 
left or right connection with a pair of nippers.

2.  Changing drain hose

  For leftward connection, bottom-leftward connection and rearleftward 

connection’s piping, it is necessary to change the drain hose and drain 
cap.

Rear right

Rear left

Bottom left

Left

Bottom right

Right

Die-cutting bush body 

slit

Take of

f cap 

and cut bush 

body slit

Changing drain hose

Piping preparation

Changing

drain  hose

Do not apply lubricating oil
(refrigerant machine oil) 
when inserting the drain 
cap. Application causes 
deterioration and drain
leakage of the plug.

Insert a hexagon wrench 
(4 mm).

No gap

•  Do not perform 

fl

 are connection inside a building or dwelling or room, 

when joining the heat exchanger of indoor unit with interconnection 
piping. Refrigerant connection inside a building or dwelling or room 
must be made by brazing or welding. Joint connection of indoor 
unit by 

fl

 aring method can only be made at outdoor or at outside of 

building or dwelling or room. Flare connection may cause gas leak 
and 

fl

 ammable atmosphere. 

WARNING

Summary of Contents for RAS-M10PKVPG-E

Page 1: ...R CONDITIONER MULTIPLE TYPE INSTALLATION MANUAL 1121451199 R32 ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH PORTUGUÊS POLSKI ČESKY HRVATSKI MAGYAR NEDERLANDS ΕΛΛΗΝΙΚΑ SVENSKA SUOMI NORSK DANSK ROMÂNĂ БЪЛГАРСКИ EESTI LATVISKI SLOVENČINA SLOVENŠČINA LIETUVIŲ PУCСКИЙ ...

Page 2: ...ole and Mounting Installation Plate 7 Piping and Drain Hose Installation 8 Indoor Unit Fixing 9 In case of Indoor unit is fixed to Installation plate with screws 9 Drainage 9 ELECTRICAL WORKS 10 Wiring Connection 10 Connecting Cable Connection 11 OTHERS 12 Gas Leak Test 12 Remote Control A B Selection 12 Test Operation 12 Auto Restart Setting 12 CONTENTS EN ...

Page 3: ...oes not require admission or repeated hospital treatment 2 Property damage means greater damage which affects assets or resources For general public use Power supply cord and connecting cable of appliance use shall be at least polychloroprene sheathed flexible cord design H07RN F or cord designation 60245 IEC66 Shall be installed in accordance with national wiring regulations This appliance must b...

Page 4: ...ELECTRIC PARTS MAY BE DAMAGED CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD PLACE THE UNIT WELL AWAY MORE THAN 2 M FROM HEAT SOURCES SUCH AS RADIATORS HEATERS FURNACE ...

Page 5: ...d possibly result in explosion and injury Thickness of copper pipes used R32 must be more than 0 8mm Never use copper pipes thinner than 0 8mm Do not perform flare connection inside a building or dwelling or room when joining the heat exchanger of indoor unit with interconnection piping Refrigerant connection inside a building or dwelling or room must be made by brazing or welding Joint connection...

Page 6: ...ter or other moisture before installation could result in electric shock Do not store it in a wet basement or expose to rain or water After unpacking the unit examine it carefully for possible damage Do not install the unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at surrounding of the unit it may cause of fire Do not install in a place that can increase ...

Page 7: ...ipple 1 for heating model only 8 Cap water proof 2 for some models only 9 Owner s Manual Installation Manual B Label 2 for Multi model The part may differ from that shown The number of parts may differ by model The part is packed with the outdoor unit Filter Clean Replacement Air filters Clean every 2 weeks 1 Open the air inlet grille 2 Remove the air filters 3 Vacuum or wash and then dry them 4 R...

Page 8: ...d wall and tilt the indoor unit for better operation For the rear left and left piping Wall 1 Batteries Flat head wood screw Remote control holder Vinyl tape Apply after carrying out a drainage test Wireless remote control Shield pipe Attach to the front panel Air filter Hook Installation plate Hook 52 mm or more 190 mm or more 225 mm or more Insulate the refrigerant pipes separately with insulati...

Page 9: ... a concrete wall with anchor bolts use the anchor bolt holes as illustrated in the below figure 3 Install the installation plate horizontally in the wall When installing the installation plate with a mounting screw do not use the anchor bolt holes Otherwise the unit may fall down and result in personal injury and property damage 1 After determining the pipe hole position on the mounting plate Æ dr...

Page 10: ...fter passing the connecting pipe through the pipe hole connect the connecting pipes to the auxiliary pipes and wrap the facing tape around them Bind the auxiliary pipes two and connecting cable with facing tape tightly In case of leftward piping and rear leftward piping bind the auxiliary pipes two only with facing tape Indoor unit Connecting cable Auxiliary pipes Installation plate Carefully arra...

Page 11: ...age 1 Run the drain hose sloped downwards 2 Put water in the drain pan and make sure that the water is drained out of doors 3 When connecting extension drain hose insulate the connecting part of extension drain hose with shield pipe NOTE The hole should be made at a slight downward slant on the outdoor side Arrange the drain pipe for proper drainage from the unit Improper drainage can result in de...

Page 12: ...l cords into the pipe hole on the wall 4 Take out the cable protrudes about 20 cm from the front 5 Insert the cable fully into the terminal block and secure it tightly with screws 6 Tightening torque 1 2 N m 0 12 kgf m 7 Secure the cable with the cord clamp 8 Fix the terminal cover and attach front panel to the indoor unit Cable about 20 cm Front panel Terminals block Main panel Terminal cover Wir...

Page 13: ...al Block Chassis CAUTION 1 The power supply must be same as the rated of air conditioner 2 Prepare the power source for exclusive use with air conditioner 3 Circuit breaker must be used for the power supply line of this air conditioner 4 Be sure to comply power supply and connecting cable for size and wiring method 5 Every wire must be connected firmly 6 Perform wiring works so as to allow a gener...

Page 14: ...r adjacent two rooms if operating a unit two units may receive the remote control signal simultaneously and operate In this case the operation can be preserved by setting either one remote control to B setting Both are set to A setting in factory shipment The remote control signal is not received when the settings of indoor unit and remote control are different There is no relation between A setti...

Reviews: