– 41 –
Item
16.
S
hort
Timer
Operation flow and applicable data, etc
De
s
cription
In the normal condition, after switching one circuit
breaker, 3-minute delay time for compressor is set for the
maintenance of the unit.
Purpo
s
e
To start the unit immediately for the
purpose of testing, trial...etc, short
timer can be used.
maintenance of the unit.
S
hort Timer
S
ettin
g
1
Push [ ] button to turn the unit
OFF.
2
S
et the operation mode on the
remote control without sending
the signal to the unit.
3
Use the tip of the pencil to push
the [CHECK] button and hold,
"00" will show on display, then
push [
S
ET] button to make "00"
disappear.
4
Push [ ] button to turn the unit
ON.
5
When short timer is activated, all
setting on the remote operates
immediately, besides, all
indications on the signal
receiving unit turns ON
continuously for 3 seconds.
17. Hi
g
h
ceilin
g
s
elect
s
witch
<How to
s
et the Hi
g
h ceilin
g
s
witch>
• Remove the cover of the electric parts box by taking off the mounting screws and pushing the hooking
section.
• There are the selector switches (
S
W501) on the P.C. board of the electric parts box.
No.1 and No.2 of the selector switches (
S
W501) are provided to select the height of the ceiling.
According to the ceiling height in the following table, select No.1 or No.2 of the selector switches
(
S
W501).
<Hei
g
ht li
s
t of ceilin
g
po
ss
ible to be in
s
talled>
Unit : m
Model
RA
S
-
Po
ss
ible in
s
talled
ceilin
g
hei
g
ht
1
3
M10,M13 type
M16 type
Up to 2.7 m
Up to 3.5 m
When using the high ceiling (1) or (3),
cold air may be felt due to the
temperature drop of discharge air.
Indoor unit
Capacity type
M10, M13 type
Discharge direction
S
tandard (Factory default)
High ceiling (1)
High ceiling (3)
4-way
2.7
—
—
4-way
2.9
3.2
3.5
M16 type
S
etup data
0000
0001
0003
S
etup of
hi
g
h ceilin
g
S
W501-1
S
W501-2
OFF
ON
OFF
OFF
OFF
ON
REMARK
S
SW501-2
SW501-1
MCU