This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling
/ dry / AUTO (cooling) mode to keep the indoor unit clean.
•
The self clean time varies with the cooling / dry / Auto (cooling) operation time as follows.
Cooling / dry / Auto (cooling) operation time
self clean time
Less than 10 minutes
No self clean operation
10 minutes to less than 1 hour
1 hour
More than 1 hour
2 hours
•
“
” is displayed on the remote controller during self clean operation.
To stop self clean forcibly, push
button twice in succession.
CAUTION
•
The fan continues to run even after
button is pushed to stop operation in some modes.
This is normal because the self clean mode is in progress.
•
The louvers open slightly and are directed horizontally during self clean, and they close when the self clean is
completed.
•
The operation lamp (LED) does not light during the self clean mode (function).
•
The self clean mode (function) cannot clean the room or remove the already existing mold and dust inside the
indoor unit.
•
To cancel the self clean function, consult the dealer.
CAUTION
Do not set the swing setup code to “0000”.
(This setting may cause a failure of the louvers.)
How to set up swing type
2
1
4
5
3
1
Push
for at least four seconds when
the air conditioner is not working.
•
, symbol, and numbers flash.
2
Select an indoor unit to be set by pushing
(left side of the button).
•
Each time you push the button, unit numbers
change as follows:
UNIT No.
1-1
UNIT No.
1-2
UNIT No.
1-3
UNIT No.
1-4
Not
display
The fan of the selected unit runs and the louvers
start swinging.
3
Select a swing type by pushing TIME
buttons.
Swing setup code
4
Push the
button.
5
Push the
button to
fi
nish the setting.
Swing setup code
Swing of louvers
0001
Standard swing
(Factory default)
0002
Dual swing
0003
Cycle swing
8
Self clean mode
9
Advanced settings
OM_1115350244_EN.indd 13
OM_1115350244_EN.indd 13
5/7/2564 13:31:02
5/7/2564 13:31:02