– 23 –
When a test run is not
performed properly
y
When a test run is not performed properly, refer
to the error code and the part to be checked on
“Troubleshooting”.
y
When a test run is executed before installing the
external duct, a protection control may be activated
and lets the unit stop and the code P12 may be
displayed. (This is not due to a malfunction but to the
current control function of the DC motor in this unit.)
When a test run executed before installing the
external duct, select “Low” for the fan speed level or
cover the air discharge.
y
In addition, stop the operation before replacing the
High-ef
fi
ciency
fi
lter or opening the service panel.
After the test run, reset the circuit breaker of the
indoor unit.
Wired remote controller
1
When TEMPORARY button is pushed for 10
seconds or more, “Pi!” sound is heard and the
operation changes to test run. After approx.
3 minutes, a cooling operation starts forcedly.
Check cool air starts blowing. If the operation
does not start, check wiring again.
2
To stop a test operation, push TEMPORARY
button once again (Approx. 1 second).
Check wiring / piping of the indoor and outdoor
units in test run.
TEMPORARY button
11
Maintenance
<Daily maintenance>
4
Cleaning of the air
fi
lter
If is displayed on the remote controller, maintain the air
fi
lter.
3
1,2
1
Push the
button to stop the operation, then
turn off the circuit breaker.
After the cooling or dry operation, the fan keeps
running for self-cleaning. Push the
button
twice to stop the operation.
1. Take out the air
fi
lter.
y
Slide and remove the
fi
lter as shown in the following
fi
gure:
WARNING
When the
fi
rst
fi
lter comes out without connected to the other one, insert it once more to connect the two
fi
lters
together and pull out them as connected. Do not insert hands to take out the second
fi
lter. You may injure
yourself.
2. Cleaning with water or vacuum cleaner.
y
If dirt is heavy, clean the air
fi
lter by tepid water with neutral detergent or water.
y
After cleaning with water, dry the air
fi
lter suf
fi
ciently in a shade place.
3. Mount the air
fi
lter.
* Insert the
fi
lters into the direction which the arrows, carved on the
fi
lters, show. (2
fi
lters are identical)
2
Turn on the circuit breaker, then push the
button on the remote controller to start the
operation.
3
After cleaning, push .
display disappears.
CAUTION
y
Do not start the air conditioner while leaving air
fi
lter removed.
y
Push the
fi
lter reset button. ( indication will be turn off.)
46-EN