– 12 –
■
Installation location
WARNING
WARNING
Install the outdoor unit properly in a location that is
durable enough to support the weight of the outdoor
unit.
Insufficient durability may cause the outdoor unit to fall,
which may result in injury.
Pay special attention when installing the unit onto a wall
surface.
CAUTION
Do not install the outdoor unit in a location that is
subject to combustible gas leaks.
Accumulation of combustible gas around the outdoor
unit may cause a fire.
Install the outdoor unit in a location that meets the
following conditions after the customer’s consent
is obtained.
• A well-ventilated location free from obstacles near
the air inlets and air outlet.
• A location that is not exposed to rain or direct
sunlight.
• A location that does not increase the operating noise
or vibration of the outdoor unit.
• A location that does not produce any drainage
problems from discharged water.
Do not install the outdoor unit in the following
locations.
• A location with a saline atmosphere (coastal area) or
one that is full of sulfide gas (hot-spring area)
(Special maintenance is required).
• A location subject to oil, vapor, oily smoke, or
corrosive gases.
• A location in which organic solvent is used.
• Places where iron or other metal dust is present. If
iron or other metal dust adheres to or collects on the
interior of the air conditioner, it may spontaneously
combust and start a fire.
• A location where high-frequency equipment
(including inverter equipment, private power
generator, medical equipment, and communication
equipment) is used (Installation in such a location
may cause malfunction of the air conditioner,
abnormal control or problems due to noise from such
equipment).
• A location in which the discharged air of the outdoor
unit blows against the window of a neighboring
house.
• A location where the operating noise of the outdoor
unit is transmitted.
• When the outdoor unit is installed in an elevated
position, be sure to secure its feet.
• A location in which drain water poses any problems.
CAUTION
1. Install the outdoor unit in a location where the
discharge air is not blocked.
2. When an outdoor unit is installed in a location that is
always exposed to strong winds like a coast or on the
high stories of a building, secure normal fan
operation by using a duct or wind shield.
3. When installing the outdoor unit in a location that is
constantly exposed to strong winds such as on the
upper stairs or rooftop of a building, apply the
windbreak measures referred to in the following
examples.
1) Install the unit so that its discharge port faces the
wall of the building.
Keep a distance 500 mm or more between the unit
and wall surface.
2) Consider the wind direction during the operational
season of the air conditioner, and install the unit so
that the discharge port is set at a right angle
relative to the wind direction.
4. When using an air conditioner under low outside
temperature conditions (outside temp.-5°C or lower)
in COOL mode, prepare a duct or snow hood so that
it is not affected by the snow.
<Example>
500 mm
Wall
Strong wind
Strong wind
Snow hood
23-EN
24-EN