Running mode indication icon

Indicate the selected running mode.

2

Central control indication icon 
It will be displayed when the air conditioner

is centrally controlled and used by a central 
remote controller and other central control 
devices. If the central control prohibits using the 
remote controller, 

 will 

fl

 ash when pressing 

the ON/OFF, mode or temperature button on 
the remote controller, indicating that these 
buttons do not work. (The settings that can be 
con

fi

 gured on the remote controller will vary 

depending on the central control mode.
For details, please read the Owner’s Manual of 
the central remote controller.)

3

Setting indication icon

Indicate that the system is checking 
automatically after the circuit breaker has been 
disconnected or other conditions have occurred.

10

Fan speed indication icon

•  Indicate the selected fan speed.

Auto

    

 

Low

 

 

    

Low +

   

    

Med.

 

 

    

Med. +

   

    

High

 

 

    

Fix

 

           

11

Timer off indication ico

When an error occurs, display the error code. 
In normal state, display the time of timer off

4

Repair indication icon

Display when performing an inspection or the 
protective device is running.

5

Test run indication icon

Display during the test run period.

6

Temperature setting indication icon

Display the selected setting temperature.

7

Wind direction indication icon

Display when the louver moves up and down.

8

Louver position indication icon

Indicate the louver position.

9

Louver locking indication icon

Display when there is a louver locking device.
(4-Way cassette type only)

12

Pre-heat indicator

Displayed when the heating mode is energized 
or defrost cycle is initiated.
While this indication is displayed, the indoor fan 
stops or operate in fan mode.

13

Remote controller sensor indication icon

Display when using the remote controller sensor.

14

Notice display

Displayed while notice code occurs.
For details, contact your dealer (distributor).

15

No function display

Displayed when the function requested is not 
available on that model.

Normal 

Operation

Operation 

mode

Fan speed

Wind 

direction

 

Indication icon

All the icons shown on the display are for illustrative purposes only. Cooling only model do not show heating-related 
icons. When “SETTING” 

fl

 ickers, the operation will not be accepted.

2

3

4

5

6

10

14

11

12

15

7

8

1

9

13

3.2 Operation

When you use the air conditioner for the 

fi

 rst time or change the settings, please follow the steps below.

From then on, press the On/Off button to run the air conditioner with the selected settings.

 

Standby

When “SETTING” 

fl

 ickers, the operation will not be accepted by system.

REQUIREMENT

•  During use, keep the power switch in open state.
•  When you use it again after a long time, please turn on the power switch at least 12 hours in advance.
•  About 1 minute after the power is turned on, the remote controller can work. This is not a fault.

– 8 – 

15-EN 

16-EN

Summary of Contents for RAV-HM1101CTP-E

Page 1: ...mercial use R32 AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name Ceiling type RAV HM401CTP E RAV HM561CTP E RAV HM801CTP E RAV HM901CTP E RAV HM1101CTP E RAV HM1401CTP E RAV HM1601CTP E English ...

Page 2: ...l capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance According to EN 60335 1 This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or ment...

Page 3: ... has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualified service person who is allowed to do the electrical work involved in installation repair relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local laws and regula...

Page 4: ... and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing cartons for storage or transportation heed the precautions written on the packing cartons Failure to heed the precautions may cause the stack to collapse The air conditioner must be transported in stabl...

Page 5: ... work required Inside the air conditioner are high voltage areas and rotating parts Due to the danger of electric shocks or of your fingers or physical objects becoming trapped in the rotating parts do not remove service panel of the outdoor unit When work involving the removal of these parts is required contact a qualified installer 1 or a qualified service person 1 Do not move or repair any unit...

Page 6: ... unit has been refitted If there is a danger of the outdoor unit s toppling over do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified installer 1 or a qualified service person 1 to have the improvements or refitting done Do not set the circuit breaker to the ON position until the improvements or refitting is completed Do not customize the unit Do...

Page 7: ...ays or other flammable materials near the air conditioner and do not spray flammable aerosol directly to the air conditioner They may catch fire Stop running the air conditioner and turn off the breaker before cleaning Otherwise injury may result as the fan is rotating at high speed inside the unit Ask for cleaning of the air conditioner to be performed by the dealer Cleaning the air conditioner i...

Page 8: ... Functions When operating the button the LCD backlight will be lightened for 15 seconds Button 1 2 3 4 Operation lamp Lights during operations Blinks when a check occurs or the protective device activates 1 ON OFF button Press the button to turn on the air conditioner and press the button again to turn off the air conditioner 2 Setting button It is used for temperature setting in general condition...

Page 9: ... moves up and down 8 Louver position indication icon Indicate the louver position 9 Louver locking indication icon Display when there is a louver locking device 4 Way cassette type only 12 Pre heat indicator Displayed when the heating mode is energized or defrost cycle is initiated While this indication is displayed the indoor fan stops or operate in fan mode 13 Remote controller sensor indication...

Page 10: ... object pre heating The air conditioner can control the heating temperature to about 8 C in the heating mode The 8 C heating operation requires settings with the wired remote controller Ask the installer or dealer for the settings according to the installation manual of the indoor unit Start 1 Set the displayed temperature to 18 C in the heating mode by pushing TEMP button 2 Set the displayed temp...

Page 11: ...ps Point the louver downward If not pointing downward hot air may not reach the floor Initial 1 2 3 4 5 6 Swing Operation mode Available directions HEAT FAN 1 2 3 4 5 6 For cooling The louver can be adjusted to four steps Point the louver horizontally If pointing downward dew may form on the surface of the air discharge port and may drop down If a louver lock setup is carried out in the position o...

Page 12: ...d installer or qualified service person to do it Do not attempt it by yourself CAUTION Do not push buttons with wet hands Doing so may result in electric shock Cleaning the air filters When the filter indicator is displayed on the remote controller clean the air filters Only for RBC AMTU and RBC AMSU remote controllers Clogged filters may lower the cooling and heating performance When the unit wil...

Page 13: ...th drainage Ornamental panel louvers Indoor Dust dirt scratches Wash them when they are contaminated or apply repair coating Exterior Outdoor Rust peeling of insulator Peeling lift of coat Apply repair coating 7 Troubleshooting If there is something unusual even after checking the above stop running the unit turn off the circuit breaker and inform the dealer where you purchased the product of the ...

Page 14: ...r on the remote controller blink If the protective device is activated Turn off the circuit breaker and perform a checkup Continued running may cause a malfunction Check whether the air filter is installed If not the heat exchanger may be clogged with dust and water leakage may occur During cooling The air intake or discharge of the outdoor unit is clogged Strong wind continuously blows against th...

Page 15: ...r pipe of the heat exchanger Do not install the air conditioner near an obstacle air vent lighting equipment etc that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality ...

Page 16: ...d if technical or operational modifications are introduced without the manufacturer s consent Declaration of Conformity Manufacturer Toshiba Carrier Thailand Co Ltd 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand TCF holder TOSHIBA CARRIER UK LTD Porsham Close Belliver Industrial Estate Roborough Plymouth Devon PL6 7DB United Kingdom Hereby...

Page 17: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1115653896 ...