Installation Manual
‒
16
‒
16-EN
6
PIPING AND DRAIN HOSE INSTALLATION
Piping and drain hose forming
* Since dewing results in a machine trouble, make sure to insulate both connecting pipes.
(Use polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right
Die-cutting
front panel slit
Piping preparation
Changing
drain hose
1. Die-cutting front panel slit
Cut out the slit on the left or right side of the front panel for the left or right connection and the slit
on the bottom left or right side of the front panel for the bottom left or right connection with a pair of
nippers.
2. Changing drain hose
For leftward connection, bottom-leftward connection and rear-leftward connection’s piping, it is
necessary to change the drain hose and drain cap.
How to remove the drain hose
• The drain hose can be removed by removing the screw securing the drain
hose and then pulling out the drain hose.
• When removing the drain hose, be careful of any sharp edges of steel plate.
The edges can injuries.
• To install the drain hose, insert the drain hose
fi
rmly until the connection part
contacts with heat insulator, and then secure it with original screw.
Drain hose