– 58 –
9. DETACHMENTS
RAV-SM561AT-E, RAV-SM801AT-E
No.
Part name
Common
procedure
Procedure
REQUIREMENT
Never forget to put on the gloves at
working time; otherwise an injury will be
caused by the parts, etc.
1. Detachment
1) Stop operation of the air conditioner, and
turn off switch of the breaker.
2) Remove the valve cover.
(ST1T Ø4 × 10, 1 pc.)
• After taking off screws, remove the valve
cover while pulling downward.
3) Remove the wiring cover (ST1T Ø4 × 8,
2 pcs.), and remove the power supply
cable and indoor/outdoor connecting
cables.
4) Remove the upper cabinet.
(ST1T Ø4 × 8, 5 pcs.)
• After taking off screws, remove the front
side of the upper cabinet while pulling
upward.
2. Attachment
1) Attach the waterproof cover.
REQUIREMENT
Be sure to attach a waterproof cover to
prevent entering of rainwater, etc.
2) Attach the upper cabinet.
(ST1T Ø4 × 8, 5 pcs)
• Hook the rear side of the upper cabinet,
and then cover the front cabinet with
upper cabinet.
3) Connect the power cable and indoor/
outdoor connecting cables to the terminal,
and then fix them with cord clamp.
(ST1T Ø4 × 10, 3 pcs)
4) Attach the wiring cover.
(ST1T Ø4 × 8, 2 pcs)
5) Attach the valve cover.
(ST1T Ø4 × 10, 1 pc)
Remarks
Valve cover
Wiring cover
Upper cabinet
Waterproof cover