Wired remote controller

This remote controller can control the operation of up to 8 indoor units.

Display section

In the display illustration below all the icons are shown. When the unit is in 
operation, only relevant icons will be displayed.   

‡

When the leak breaker is turned on at the first time, 

 flashes on the 

display part of the remote controller. 

‡

While this icon is flashing, the model is being automatically confirmed. 
Wait till 

 icon has disappeared to use the remote controller.

1

Operation mode

The selected operation mode is displayed.

2

Error display

Displayed while the protective device works or an 
error occurs.

3

SETTING display

Displayed during setup of the timer or other 
settings.

4

TEST run display

Displayed during a test run.

5

Timer display

The selected timer time is displayed.
When an error occurs, error code is displayed.

6

Timer mode display

The selected timer mode is displayed.

7

Filter display

Reminder to clean the air filter.

8

Fan speed display

The selected fan speed mode is displayed.

9

Set temperature display

The selected set temperature is displayed.

10

Power saving mode display

Limits compressor speed (capacity) to save 
energy.

SET

TIME

TIMER SET

TEST

FILTER

RESET

TEMP.

CL

FAN

SAVE

SWING/FIX

VENT

MODE

ON / OFF

UNIT  LOUVER

Display 

section

Operation 

section

1

8

6

16

4

2

3

5
7

13

15

14 17

9

12

1110

(Auto)
(High)
(Med.)
(Low)

11

UNIT No. display

The selected indoor unit number is displayed.
Also number of indoor or outdoor unit which an 
error occurs is displayed.

12

Central control display

Displayed when the air conditioner is used under 
the central control in combination with a central 
control remote controller.

In case the remote controller is disabled by the 
central control system, 

 flashes.

The button operation is not accepted. 

Even when ON / OFF, MODE, or TEMP. button is 
pushed, and the button operation is not accepted. 
(Settings made by the remote controller vary with 
the central control mode. For details, refer to the 
Owner’s Manual of the central control remote 
controller.)

13

Remote controller sensor display

Displayed while the sensor of the remote controller 
is used.

14

Pre-heat display

Displayed when the heating mode is energized or 
defrost cycle is initiated.
While this icon is displayed, the indoor fan stops.

15

No function display

Displayed when the function requested is not 
available on that model.

16

1

6

4

2

3

5
7

13

15

14

9

12

11 10

8

16

17

Service display

17

Operation ready display

This display appears on some models.

15-EN

16-EN

1116950231_EN.indd   8

1116950231_EN.indd   8

5/9/19   1:50 PM

5/9/19   1:50 PM

Summary of Contents for RAV-SM1101DTP-A

Page 1: ...PLIT TYPE Owner s Manual Indoor Unit Model name Concealed Duct High Static Pressure Type English 1116950231 RAV SM1101DTP A RAV SM1401DTP A RAV SM1601DTP A 1116950231_EN indd cover1 1116950231_EN indd cover1 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Page 2: ...dren without supervision According to IEC 60335 1 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play wi...

Page 3: ...o installs repairs maintains relocates and removes the air conditioners made by Toshiba Carrier Corporation He or she has been trained to install repair maintain relocate and remove the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with th...

Page 4: ...ual WARNING General Carefully read Owner s Manual before starting the air conditioner There are many important things to keep in mind for daily operation Ask for installation to be performed by the dealer or a professional Only a qualified installer 1 is able to install an air conditioner If a non qualified person installs an air conditioner it may result in problems such as fire electric shock in...

Page 5: ... the electrical control box cover of the indoor unit or service panel of the outdoor unit set the circuit breaker to the OFF position Failure to set the circuit breaker to the OFF position may result in electric shocks through contact with the interior parts Only a qualified installer 1 or qualified service person 1 is allowed to remove the electrical control box cover of the indoor unit or servic...

Page 6: ...on 1 arrives Continuing to use the air conditioner in the trouble status may cause mechanical problems to escalate or result in electric shocks or other trouble If the fan guard is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified service person 1 to have the repairs done Do not set the circuit breaker to the ON position until the repa...

Page 7: ... or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result in the unit s falling down and causing injury Do not leave flammable sprays or other flammable materials near the air conditioner and do not spray flammab...

Page 8: ...EN Information on the transportation handling and storage of the carton Examples of indication on the carton Symbol Description Symbol Description Keep dry Do not drop Fragile Do not lay down Stacking height 6 cartons can be stacked in this case Do not walk on this carton This side up Do not step Handle with care Other cautions Description CAUTION Injury possibility Don t handle with packing band ...

Page 9: ... TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 8 6 16 4 2 3 5 7 13 15 14 17 9 12 11 10 Auto High Med Low 11 UNIT No display The selected indoor unit number is displayed Also number of indoor or outdoor unit which an error occurs is displayed 12 Central control display Displayed when the air conditioner is used under the cent...

Page 10: ...be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Preparation When the circuit breaker is turned on the partiti...

Page 11: ... maintenance of the air conditioner 1 Set the displayed temperature to 18 C in the heating mode by pushing TEMP button 2 Set the displayed temperature to 8 C by pushing TEMP button for at least 4 seconds 1 Set the displayed temperature to 18 C by pushing TEMP button The air conditioner returns to the normal HEAT mode Select a desired temperature and operation mode 5 Timer operation Three timer mod...

Page 12: ...ettings see To configure the power saving settings in Power saving mode Even when operation start stop operation mode change or power reset is performed during the power saving mode the power saving mode is retained until the next operation 7 Maintenance WARNING Cleaning the air filter and other parts of the air filter involves dangerous work in high places so be sure to have a qualified installer...

Page 13: ...e circuit breaker and inform the dealer where you purchased the product of the product number and symptom Do not attempt to repair the unit by yourself as doing so is dangerous If the check indicator e g is displayed on the remote controller LCD inform the dealer of its content as well If any of the following occur stop running the unit immediately turn off the circuit breaker and contact the deal...

Page 14: ...defrosting operation During the defrosting operation the defrosted water will be drained from the bottom plate of the outdoor unit Heating capacity In the heating operation the heat is absorbed from the outside and brought into the room This way of heating is called heat pump system When the outside temperature is too low it is recommended to use another heating apparatus in combination with the a...

Page 15: ...in an acidic or alkaline atmosphere in a hot spring area or near a chemicals factory or in a place subject to combustion emissions Corrosion may be generated on the aluminum fin and copper pipe of the heat exchanger Do not install the air conditioner near an obstacle such as air vent lighting equipment that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do n...

Page 16: ... 15 MEMO 1116950231_EN indd 15 1116950231_EN indd 15 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Page 17: ... 16 EN ID ID MEMO 1116950231_EN indd 16 1116950231_EN indd 16 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Page 18: ... 17 MEMO 1116950231_EN indd 17 1116950231_EN indd 17 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Page 19: ...1116950231_EN indd 18 1116950231_EN indd 18 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Page 20: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1116950231 1116950231_EN indd 19 1116950231_EN indd 19 5 9 19 1 50 PM 5 9 19 1 50 PM ...

Reviews: