background image

– 13 –

Ceiling type

Owner’s Manual

Ceiling type

Owner’s Manual

12

Installation

Do not install the air conditioner in the following places

• Do not install the air conditioner in any place within 1 m from a TV, stereo, or radio set. If the unit is installed in 

such place, noise transmitted from the air conditioner affects the operation of these appliances.

• Do not install the air conditioner near a high frequency appliance (sewing machine or massager for business use, 

etc.), otherwise the air conditioner may malfunction.

• Do not install the air conditioner in a humid or oily place, or in a place where steam, soot, or corrosive gas is 

generated.

• Do not install the air conditioner in a salty place such as seaside area.
• Do not install the air conditioner in a place where a great deal of machine oil is used.
• Do not install the air conditioner in a place where it is usually exposed to strong wind such as in seaside area.
• Do not install the air conditioner in a place where sulfureous gas generated such as in a spa.
• Do not install the air conditioner in a vessel or mobile crane.
• Do not install the air conditioner in an acidic or alkaline atmosphere (in a hot-spring area or near a chemicals 

factory, or in a place subject to combustion emissions). Corrosion may be generated on the aluminum fin and 
copper pipe of the heat exchanger.

• Do not install the air conditioner near an obstacle (air vent, lighting equipment, etc.) that disturbs discharge air. 

(Turbulent airflow may reduce the performance or disable devices.)

• Do not use the air conditioner for special purposes such as preserving food, precision instruments, or art objects, 

or where breeding animals or growing plants are kept. 

 

(This may degrade the quality of preserved materials.)

• Do not install the air conditioner over an object that must not get wet. (Condensation may drop from the indoor 

unit at a humidity of 80 % or more or when the drain port is clogged.)

• Do not install the air conditioner in a place where an organic solvent is used.
• Do not install the air conditioner near a door or window subject to humid outside air. 

 

Condensation may form on the air conditioner.

• Do not install the air conditioner in a place where special spray is used frequently.

Be careful with noise or vibrations

• Do not install the air conditioner in a place where noise by outdoor unit or hot air from its air discharge annoys 

your neighbors.

• Install the air conditioner on a solid and stable foundation so that it prevents transmission of resonating, operation 

noise and vibration.

• If one indoor unit is operating, some sound may be audible from other indoor units that are not operating.

13

Specifications

* Under 70 dBA

Model

Sound power level (dBA)

Weight (Kg)

Cooling

Heating

RAV-SM564CT-E

*

*

21

RAV-SM804CT-E

*

*

25

RAV-SM1104CT-E

*

*

33

RAV-SM1404CT-E

*

*

33

25-EN

26-EN

+00EH99938101_01EN.book  Page 13  Tuesday, April 12, 2011  1:25 PM

Summary of Contents for RAV-SM1104CT-E

Page 1: ...Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name Ceiling Type RAV SM564CT E RAV SM804CT E RAV SM1104CT E RAV SM1404CT E 00EH99938101_01EN book Page 1 Tuesday April 12 2011 1 25 PM ...

Page 2: ...relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or ...

Page 3: ...e boundary line with a neighbour install the air conditioner while considering the noise Transportation and storage To transport the air conditioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing ...

Page 4: ...ric shocks or other trouble If the fan grille is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified service person to have the repairs done Do not set the circuit breaker to the ON position until the repairs are completed If there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to the...

Page 5: ...e In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Part Names Indoor unit Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Horizontal louver Vertical grille Air discharge The air discharge direction can be changed Air intake grille Air is taken in through here Air filter ...

Page 6: ... The selected fan speed mode is displayed 11Set temperature display The selected set temperature is displayed 12 Power saving mode display Limits compressor speed capacity to save energy Auto High Med Low 1 6 4 2 3 5 9 15 17 16 11 14 13 12 10 19 20 18 8 7 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control displ...

Page 7: ...the surrounding of the remote controller can also be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct Usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Preparation...

Page 8: ...s available during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe p...

Page 9: ...t position and then push again SWING is displayed and the up down wind direction is automatically selected Display during swinging How to stop swinging 1 Push at a desired position while the louver is swinging When is pushed after that wind direction can be set again from the highest position However even if is pushed while the louver is swinging the louver position is displayed as follows and hig...

Page 10: ...m current is limited to approximately 75 factory default of the normal mode To adjust the power save settings see To configure the power saving mode settings in Power Saving Mode Even when operation start stop operation mode change or power reset is performed during the power saving mode the power saving mode is retained until the next operation 8 Self Clean Operation Mode This function is provide...

Page 11: ...at the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general rule when...

Page 12: ... and contracts slightly due to temperature change Various smells from the walls carpet clothes cigarette cosmetics etc adhere to the air conditioner The fan keeps running to self clean operation the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote controller ar...

Page 13: ...ator on the remote controller blink If the protective device is activated Turn off the circuit breaker and perform a checkup Continued running may cause a malfunction Check whether the air filter is installed If not the heat exchanger may be clogged with dust and water leakage may occur During cooling The air intake or discharge of the outdoor unit is clogged Strong wind continuously blows against...

Page 14: ...anger Do not install the air conditioner near an obstacle air vent lighting equipment etc that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality of preserved materials ...

Page 15: ...td Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type RAV SM564CT E RAV SM804CT E RAV SM1104CT E RAV SM1404CT E Commercial name Digital Inverter Series Super Digital Inverter Series Air Conditioner Complies with the provisions of the Machinery Directive Directive 2006 42 E...

Page 16: ...CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00EH99938101_01EN book Page 33 Tuesday April 12 2011 1 25 PM ...

Reviews: