– 41 –
6-2.
Chec
k Code List (Indoor)
(Indoor unit detected)
When this w
ar
ning w
as detected bef
ore g
roup constr
uction/address chec
k finish at po
w
er supply w
as tur
ned on, the mode shifts
automatically to A
U
TO
address setup mode
.
(Central contr
ol de
vices detected)
NO
TE:
E
ven f
or the same contents of error such as comm
unication error
, the displa
y of chec
k code ma
y diff
er according to detection de
vice
.
When remote controller or centr
al controller detects an error
, it is not necessar
ily related to oper
ation of the air conditione
r. In this list, the chec
k codes that outdoor unit detects are not descr
ibed.
Explanation of err
or contents
No communication from remote controller and netw
or
k adapter
(Also no comm
unication from centr
al control system)
There is error on ser
ial comm
unication betw
een indoor and outdoor units
Same address as y
ours w
as detected.
MCU comm
unication error betw
een main motor and micro computer
Regular communication betw
een indoor master and f
ollo
wer units is impossib
le
.
Open/shor
t w
as detected on heat e
xchanger (TCJ).
Open/shor
t w
as detected on heat e
xchanger (TC).
Open/shor
t w
as detected on room temp
. sensor (T
A).
EEPR
OM error (Other error ma
y be detected.
If no error
, automatic address is repeated.
There are m
ultiple master units in a g
roup
.
When e
ven one g
roup connection indoor unit e
xists in individual indoor unit.
Indoor g
roup address is unset.
Capacity of indoor unit is unset.
Duplicated setting of centr
al control system address
Abnor
mal stop b
y outside error (CN80) input
An error of indoor A
C
fan w
as detected.
(F
an motor ther
mal rela
y w
or
ked.)
Float s
witch wo
rk
ed.
Indoor DC f
an error (Ov
er-current/Loc
k,
etc.)
w
as detected.
Static pressure error set
In heating operation, an error w
as detected b
y temp
. do
wn of indoor heat e
xchanger sensor
.
Follo
wer unit in g
roup cannot operate b
y w
ar
ning from [E03/L03/L07/L08] of master unit.
Air conditioner operation
Automatic
Operation
reset
continuation
{
×
{
×
{
×
{
×
{
×
{
×
{
×
{
×
×× ×× ×× ×× ××
{
×
×× ×× ×× ××
{
×
{
×
Chec
k code indication
TCC-LINK central
C05
C06
C12
P30
Representative def
ective position
Centr
al control system comm
unication (send) error
Centr
al control system comm
unication (receiv
e) error
Gener
al-pur
pose de
vice control interf
ace batched w
ar
ning
Group f
ollo
w
er unit is def
ectiv
e.
Explanation of err
or contents
Signal sending oper
ation of centr
al control system is impossib
le
. There are m
ultiple same centr
al de
vices
. (AI-NET)
Signal receiving oper
ation of centr
al control system is impossib
le
.
An error on de
vice connected to gener
al-pur
pose de
vice control interf
ace of e
xclusiv
e to
TCC-LINK/AI-NET
Group f
ollo
w
er unit is def
ectiv
e.
(F
or remote controller
, abo
ve-mentioned [
∗∗∗
] details are displa
yed with unit No
.)
Air conditioner operation
Automatic
Operation
reset
continuation
——
——
——
——
Chec
k code indication
Remote contr
oller
E01
E02
E09
Representative def
ective position
No master remote controller
, Remote controller comm
unication (Receiv
e) error
Remote controller comm
unication (Send) error
Duplicated master remote controller
Explanation of err
or contents
Signal cannot be receiv
ed from indoor unit.
Master remote controller w
as not set.
(including 2 remote controllers)
Signal cannot be sent to indoor unit.
In 2-remote controller control, both were set as master
.
(Indoor master unit stops w
ar
ning and f
ollo
w
er unit contin
ues oper
ation.)
Air conditioner operation
Automatic
Operation
reset
continuation
——
——
×
Chec
k code indication
TCC-LINK central & Remote contr
oller
E03
E04
E08
E10
E18
F01
F02
F10
F29
L03
L07
L08
L09
L20
L30
P01
P10
P12
P19
P31
Representative def
ective position
Regular comm
unication error betw
een indoor and remote controller
Indoor/Outdoor ser
ial error
Duplicated indoor addresses
Comm
unication error betw
een indoor MCU
Regular comm
unication error betw
een indoor master and f
ollo
wer units
Indoor unit, Heat e
xchanger (TCJ) error
Indoor unit, Heat e
xchanger (TC) error
Indoor unit, Room temp
. sensor (T
A) error
Indoor unit, other indoor P
.C
. board error
Duplicated setting of indoor g
roup master unit
There is g
roup cab
le in individual indoor unit.
Unset indoor g
roup address
Unset indoor capacity
Duplicated centr
al control system address
Outside error input to indoor unit (Inter
loc
k)
Indoor unit, A
C
fan error
Indoor unit, o
verflo
w detection
Indoor unit, DC f
an error
4-w
ay
v
al
ve system error
Other indoor unit error
(Remote contr
oller detected)
Summary of Contents for RAV-SM1106BT-E
Page 18: ... 18 ...
Page 19: ... 19 3 WIRING DIAGRAM ...
Page 34: ... 34 5 3 Indoor Print Circuit Board MCC 1631 ...
Page 89: ... 89 11 EXPLODED VIEWS AND PARTS LIST 11 1 RAV SM406BT E RAV SM456BT E RAV SM566BT E ...
Page 91: ... 91 11 2 RAV SM806BT E ...
Page 93: ... 93 11 3 RAV SM406BT TR RAV SM456BT TR RAV SM566BT TR ...
Page 95: ... 95 11 4 RAV SM806BT TR ...
Page 98: ... 98 11 6 RAV SM1106BT E RAV SM1406BT E RAV SM1606BT E ...
Page 100: ... 100 11 7 RAV SM1106BT TR RAV SM1406BT TR RAV SM1606BT TR ...