– 98 –
Concealed Duct High Static Pressure
Installation Manual
Concealed Duct High Static Pressure
Installation Manual
Procedure
6
If there is other indoor unit to be changed, repeat
procedure
2
to
5
to change the setup.
When the above setup has finished, push
to select
the indoor UNIT No. before change of setup, specify CODE
No.
[12]
,
[13]
,
[14]
in order with TEMP.
/
buttons,
and then check the changed contents.
Address change check Before change:
[3-3-1]
→
After change:
[2-2-2]
Pushing button clears the contents of which setup was
changed. (In this case,
procedure
from
2
is repeated.)
Procedure
7
After check of the changed contents, push
button.
(Setup is determined.)
When pushing
button, the display disappears and the
status becomes the usual stop status.
(When pushing
button the operation from the remote
controller is not accepted for approx. 1 minute.)
∗
If the operation from the remote controller is not
accepted even 1 minute or more passed after pushing
button, it is considered that the address setup is
incorrect.
In this case, the automatic address must be again set
up.
Therefore repeat procedure of the setup change from
the
Procedure
1
.
To recognize the position of the
corresponding indoor unit though the
indoor UNIT No. is known
Check the position during operation stop.
(Be sure to stop operation of the set.)
Procedure
1
Push simultaneously
+
buttons for 4 seconds or
more. After a while, the display part flashes and the
display appears as shown below.
In this time, the position can be checked because fan of
the indoor unit operate.
• For the group control, the indoor UNIT No. is displayed
as [
] and fans of all the indoor units in the group
control operate.
Check the displayed CODE No. is
[01]
.
• When the CODE No. is other than
[01]
, push
button
to erase the display and repeat procedure from the first
step. (After pushing
button, operation of the remote
controller is not accepted for approx. 1 minute.)
Procedure
2
In the group control, every pushing
button, the
indoor UNIT No. in the group control is displayed in order.
In this time, the position of the indoor unit can be
confirmed because only fan of the selected indoor unit
operate.
(For a group control, No. of the firstly displayed indoor unit
becomes the header unit.)
Procedure
3
After confirmation, push
button to return the mode to
the usual mode.
When pushing
button, the display disappears and the
status becomes the usual stop status.
(When pushing
button the operation from the remote
controller is not accepted for approx. 1 minute.)
Indoor unit No. before setup change is displayed.
2
1,3
1
(
∗
Display changes according to
the model No. of indoor unit.)
n
8°C Operation
Pre-heating operation can be set for cold regions where
room temperature drops to below zero.
Procedure
1
Push simultaneously
+ +
buttons for 4 seconds
or more when the air conditioner is not working.
After a while, the display part flashes as shown below.
Check the Displayed CODE No. is
[10]
.
• When the CODE No. is other than
[10]
, push
button
to erase the display and repeat procedure from the first
step. (After pushing
button, operation of the remote
controller is not accepted for approx. 1 minute.)
(
∗
Display changes according to
the model No. of indoor unit.)
Procedure
2
Every pushing
button, the indoor unit No. in the
group control is displayed in order.
Select the indoor unit of which setup is changed.
In this time, the position of the indoor unit of which setup is
changed can be confirmed because fan of the selected
indoor unit operate.
Procedure
3
Using TEMP.
/
buttons, specify CODE No.
[d1]
.
Procedure
4
Using TIME
/
buttons, select SET DATA
[0001]
.
Procedure
5
Push
button.
In this time, the setup finishes when the display changes
from flashing to lighting.
Procedure
6
Push
button. (Setup is determined.)
When pushing
button, the display disappears and the
status
Becomes the usual stop status.
(When pushing
button the operation from the remote
controller is not accepted for approx. 1 minute.)
SET DATA
0000
0001
8°C Operation setting
None (Factory default)
8°C Operation setting
– 33 –
– 34 –