background image

– 35 –

11

Specifications

* Under 70 dBA

Model

Sound power level (dBA)

Weight (Kg)

Cooling

Heating

RAV-SM304SDT-E

*

*

22

RAV-SM404SDT-E

*

*

22

RAV-SM454SDT-E

*

*

22

RAV-SM564SDT-E

*

*

22

Declaration of Conformity

NOTE

This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer’s consent.

Manufacturer:

Toshiba Carrier Corporation 
336 Tadehara, Fuji-shi, Shizuoka-ken 416-8521 JAPAN

Authorized 
Representative / 
TCF holder:

Nick Ball 
Toshiba EMEA Engineering Director 
Toshiba Carrier UK Ltd. 
Porsham Close, Belliver Industrial Estate, 
PLYMOUTH, Devon, PL6 7DB. 
United Kingdom

Hereby declares that the machinery described below:

Generic Denomination:

Air Conditioner

Model / type:

RAV-SM304SDT-E
RAV-SM404SDT-E
RAV-SM454SDT-E
RAV-SM564SDT-E

Commercial name:

Digital Inverter Series / Super Digital Inverter Series Air Conditioner

Complies with the provisions of the “Machinery” Directive (Directive 2006 / 42 / EC) and the regulations 
transposing into national law

Complies with the provisions of the following harmonized standard:

EN 378-2: 2008+A2:2012

69-EN

70-EN

+00EH99940201-1_01EN.book  Page 35  Wednesday, October 8, 2014  11:04 AM

Summary of Contents for RAV-SM304SDT-E

Page 1: ...e For commercial use AIR CONDITIONER SPLIT TYPE Indoor Unit Model name Slim Duct Type RAV SM304SDT E RAV SM404SDT E RAV SM454SDT E RAV SM564SDT E Owner s Manual 00EH99940201 1_01EN book Page 1 Wednesday October 8 2014 11 04 AM ...

Page 2: ...us thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refr...

Page 3: ...position and contact a service person If the unit is installed in a small room take appropriate measures to prevent the refrigerant from exceeding the limit concentration even if it leaks Consult the dealer from whom you purchased the air conditioner when you implement the measures Accumulation of highly concentrated refrigerant may cause an oxygen deficiency accident Do not install the air condit...

Page 4: ...in hose for perfect draining Improper drainage may cause flooding in the house and getting furniture wet Connect the air conditioner to an exclusive power supply of the rated voltage otherwise the unit may break down or cause a fire Confirm that the outdoor unit are fixed on the base Otherwise falling down of the units or other accidents may occur Operation Do not use this air conditioner for spec...

Page 5: ...ien qualifié La personne d entretien qualifiée est une personne qui installe répare entretient déplace et enlève les climatiseurs fabriqués par Toshiba Carrier Corporation Il ou elle a été formé pour installer réparer entretenir déplacer et enlever les climatiseurs fabriqués par Toshiba Carrier Corporation ou alternativement il ou elle a reçu des consignes pour de telles opérations par une ou des ...

Page 6: ...TEST run display Displayed during a test run 8 Set temperature display The selected set temperature is displayed 9 Remote controller sensor display Displayed while the sensor of the remote controller is used 10 Pre heat display Displayed when the heating mode is energized or defrost cycle is initiated While this icon is displayed the indoor fan stops 11 No function display Displayed when the funct...

Page 7: ...tilation button If No function is displayed on the remote controller when pushing the Ventilation button a fan is not connected 5 button Filter reset button Resets Erases FILTER display 6 button Power save operation SAVE button is used for power save operation 7 button Swing Wind direction button No Function 8 Operation lamp Lamp is lit during the operation Lamp is off when stopped Although it fla...

Page 8: ...after approximately 3 to 5 minutes After the heating operation has stopped FAN operation may continue for approx 30 seconds When the room temperature reaches the set temperature and the outdoor unit stops the super low wind is discharged and the air volume decreases excessively During defrost operation the fan stops so that cool air is not discharged HEAT READY is displayed When the room temperatu...

Page 9: ... you push while the OFF timer function of the air conditioner is active the indication of the timer function disappears and then appears again after about 5 seconds This is due to normal processing of the remote controller OFF timer The operation stops when the time of timer has reached the set time Repeat OFF timer Every time the operation stops after the set time has passed ON timer The operatio...

Page 10: ...units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general rule when an indoor unit is operate...

Page 11: ...ue to temperature change Various smells from the walls carpet clothes cigarette cosmetics etc adhere to the air conditioner The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote controller are blinking Check again The room does not cool down or warm up Is the air intake or discharge of the outd...

Page 12: ... safety protection may work Cooling operation Outdoor temperature 15 C to 43 C Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 15 C to 15 C Wet bulb temp Room temperature 1...

Page 13: ...MEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type RAV SM304SDT E RAV SM404SDT E RAV SM454SDT E RAV SM564SDT E Commercial name Digital Inverter Series Super Digital Inverter Series Air Conditioner Complies with the provisions...

Page 14: ... 36 MEMO 00EH99940201 1_01EN book Page 36 Wednesday October 8 2014 11 04 AM ...

Page 15: ... 37 MEMO 00EH99940201 1_01EN book Page 37 Wednesday October 8 2014 11 04 AM ...

Page 16: ... 38 MEMO 00EH99940201 1_01EN book Page 38 Wednesday October 8 2014 11 04 AM ...

Page 17: ...ss city country 23 17 Takanawa 3 Chome Minatoku Tokyo 108 8580 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom EH99940201 1 00EH99940201 1_01EN book Page 39 Wednesday October 8 2014 11 04 AM ...