Toshiba
WARNING
General
Before starting to repair the air conditioner, read carefully through the Service Manual, and repair the air
conditioner by following its instructions.
Only qualified service person (*1) is allowed to repair the air conditioner.
Repair of the air conditioner by unqualified person may give rise to a fire, electric shocks, injury, water leaks
and/or other problems.
Do not use any refrigerant different from the one specified for complement or replacement.
Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure
or explosion of the product or an injury to your body.
Only a qualified installer (*1) or qualified service person (*1) is allowed to carry out the electrical work of the air
conditioner.
Under no circumstances must this work be done by an unqualified individual since failure to carry out the work
properly may result in electric shocks and/or electrical leaks.
When transporting the air conditioner, wear shoes with protective toe caps, protective gloves and other
protective clothing.
Inside the air conditioner are high-voltage areas and rotating parts. Due to the danger of electric shocks or of
your fingers or physical objects becoming trapped in the rotating parts, do not remove the front panel of the
indoor unit or service panel of the outdoor unit. When work involving the removal of these parts is required,
contact a qualified installer(*1) or a qualified service person(*1).
When connecting the electrical wires, repairing the electrical parts or undertaking other electrical jobs, wear
gloves to provide protection for electricians and from heat, insulating shoes and clothing to provide protection
from electric shocks.
Failure to wear this protective gear may result in electric shocks.
When checking the electrical parts, removing the cover of the electrical control box of Indoor Unit and/or service
panel of Outdoor Unit inevitably to determine the failure, use gloves to provide protection for electricians and
from heat, insulating shoes, clothing to provide protection from electric shock and insulating tools. Do not touch
the live part. Electric shock may result. Only "Qualified service person (*1)" is allowed to do this work.
When checking the electrical parts, removing the cover of the electrical control box of Indoor Unit and/or front
panel of Outdoor Unit inevitably to determine the failure, put a sign "Do not enter" around the site before the
work. Failure to do this may result in third person getting electric shock.
Electrical wiring work shall be conducted according to law and regulation in the community and installation
manual. Failure to do so may result in electrocution or short circuit.
Only a qualified installer (*1) or qualified service person (*1) is allowed to undertake work at heights using a
stand of 50 cm or more or to remove the front panel of the indoor unit to undertake work.
When working at heights, use a ladder which complies with the ISO 14122 standard, and follow the procedure
in the ladder’s instructions.
Also wear a helmet for use in industry as protective gear to undertake the work.
When working at heights, put a sign in place so that no-one will approach the work location, before proceeding
with the work.
Parts and other objects may fall from above, possibly injuring a person below.
While carrying out the work, wear a helmet for protection from falling objects.
Wear protective gloves and safety work clothing during installation, servicing and removal.
Do not touch the aluminum fin of the outdoor unit.
You may injure yourself if you do so. If the fin must be touched for some reason, first put on protective gloves
and safety work clothing, and then proceed.
Do not climb onto or place objects on top of the outdoor unit.
You may fall or the objects may fall off of the outdoor unit and result in injury.
When transporting the air conditioner, wear shoes with additional protective toe caps.
When transporting the air conditioner, do not take hold of the bands around the packing carton.
You may injure yourself if the bands should break.
Use wiring that meets the specifications in the Installation Manual and the stipulations in the local regulations
and laws. Use of wiring which does not meet the specifications may give rise to electric shocks, electrical
leakage, smoking and/or a fire.
This air conditioner has passed the pressure test as specified in IEC 60335-2-40 Annex EE.