– 16 –

EN

6

Limited operation by twin and group 

combination

NOTE

• Twin combination

The combination where 2 indoor units are installed for 1 outdoor unit.

• Group combination

Operate air conditioners in more than one system (such as single combination and twin combination) in same time.

• Header unit

The representative unit during twin and group operation. Receive commands from remote controller and transmit the 
commands to follower units.
(The header unit is indoor unit that receives START / STOP signal from the wireless remote controller.)

• Follower unit

Indoor units other than the header unit are called follower unit.

CAUTION

When using indoor unit in group control,

1. Hi POWER operation will not function.

When Hi POWER is transmitted from wireless remote controller the receiving sound will be heard from the indoor unit and display 
on the wireless remote controller will also change. However, the indoor unit does not operate Hi POWER operation. Restore the 
display on the wireless remote controller pushing Hi POWER button.

2. COMFORT SLEEP

When COMFORT SLEEP is transmitted from wireless remote controller, the receiving sound will be heard from the indoor unit 
and the display on the wireless remote controller will also be changed as same as Hi POWER operation. However, the set 
temperature and the fan speed will not be automatically adjusted. Only off timer function is activated.

3. Units other than the Header unit cannot be operated with remote controller and the TEMPORARY operation.

When operating air conditioner with wireless remote controller transmission should be sent to the Header unit.
Header and follower indoor units are decided through address setting upon installation. Follower unit will not receive any signals 
from wireless remote controller.
Air conditioner will not work even if the 

 button on the follower unit is pressed.

(Some Follower units may receive SWING and FIX, but these operations are performed only on the unit that received the signal.)
(When wireless remote controller is used, only the Header unit receives SWING signal. If the SWING signal is transmitted to 
follower unit, the sound to refuse receiving signal (3 beeps) is heard and the follower unit does not receive the signal.
For FIX operation, both Header and follower unit perform the operation by itself.
When wired remote controller is used, airflow direction can be changed on each unit by selecting the indoor unit.)

4. TIMER lamp lights up only on the Header unit.

When the timer is set with wired remote controller, even the TIMER lamp on the Header unit will not light up.

Example of twin combination

Example of group combination

Remote 

controller

Outdoor

Control line
Other connecting line

Indoor

Indoor

Indoor

Indoor

Indoor

Remote 

controller

Outdoor

Outdoor

Outdoor

7

Auto restart operation

This air conditioner is equipped with an Automatic 
restarting facility which allows the air conditioner to 
resume the set operating conditions in the event of a 
supply power shutdown without the use of the remote 
controller.
The operation will resume without warning three 
minutes after the power is restored.

NOTE

The Auto Restart Operation is not set to work on 
shipment from the factory, and so it is necessary to set it 
to function as required.

How to set the auto restart

To set the auto restart function, proceed as follows:
The power supply to the unit must be on the function 
will not set if the power is off.
To enable the auto restart function, push the 
TEMPORARY button continually for more than 3 
seconds, less than 10 seconds.
The air conditioner will acknowledge the setting and 
beep 2 times (first long, second short sound) and 

 

lamp is flashing 5 seconds (5 Hz). The system will now 
restart automatically.
The above auto restart settings can be carried out:

How to cancel the auto restart

To cancel the auto restart operation, proceed as 
follows:
Repeat the setting procedure: the air conditioner will 
acknowledge the instruction and beep 2 times (first 
long, second short sound).
The air conditioner will now require to be manually 
restarted with the remote controller after the main 
supply is turned off.
Cancellation is carried out:

TEMPORARY button

TEMPORARY button

31-EN

32-EN

+001111055901_01EN.book  Page 16  Monday, September 5, 2011  2:23 PM

Summary of Contents for RAV-SM566KRT-E

Page 1: ...xxxxxxxxxxxxxxxx xx Xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xx Xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xx Xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xx Xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xx Xxxxxxx AIR CONDITIONER SPLIT TYPE Indoor Unit Model name High Wall Type RAV SM566KRT E RAV SM806KRT E Owner s Manual For commercial use 001111055901_01EN book Page 1 Monday September 5 2011 2 23 PM ...

Page 2: ...knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work o...

Page 3: ...th a neighbour install the air conditioner while considering the noise Transportation and storage To transport the air conditioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing cartons for storag...

Page 4: ...ic shocks or other trouble If the fan grille is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified service person 1 to have the repairs done Do not set the circuit breaker to the ON position until the repairs are completed If there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to th...

Page 5: ...tice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Accessory parts 3 Parts name Indoor unit Remote controller Remote controller holder Batteries two SET TIME TIMER SET TEST FILTER RESET CL FAN SAVE SWING FIX VENT MODE UNIT LOUVER 11 10 7 8 9 6 5 3 4 1 2 1 Room temperature sensor 2 Front panel 3 Air intake grille 4 Air filte...

Page 6: ...ems and units When the power is turned on the next time lamp lights up for approximately 1 minute While the above lamp is on all the commands from the remote controller cannot be received However this is not a malfunction or failure When local prohibition is set by the central control from other equipment no signal is received even if the remote controller button is pressed However a signal of STA...

Page 7: ...ESET button Press this button to change the operation mode to the preferred operation mode memorized previously To memorize the operation mode press this button for at least 3 seconds during the preferred operation mode is displayed and the operation mode is memorized 14 SLEEP button Press this button to start the OFF timer operation that automatically adjusts the room temperature and the fan spee...

Page 8: ... controller for more than one month A C L 4 2 Adjusting clock Setting the clock Before you start operating the air conditioner set the clock of the remote controller using the procedures given in this section The clock panel on the remote controller will indicate the time regardless of whether the air conditioner is in use or not Initial setting When batteries are inserted in the remote controller...

Page 9: ...ls can be received by the indoor unit Mounting and removing the remote controller To mount the remote controller hold it parallel to the remote controller holder and push it in fully To remove the remote controller slide the remote controller upwards and out from the holder 7 m 4 4 How to use remote controller Cooling heating fan only operation Start 1 START STOP button Press this button to start ...

Page 10: ...r operation mode the settings are saved in the remote controller Thereafter the air conditioner will start operating under the same conditions when you simply press the ON OFF button of the remote controller If the clock display is flashing you cannot set the timer Follow the instructions in the section Setting the clock and then set the timer Combined timer Setting both ON and OFF timers simultan...

Page 11: ...erating status by automatically setting the fan speed to the lowest speed Setting QUIET mode 1 QUIET button Press the QUIET button after starting any operation At the same time the mark is indicated Cancelling QUIET mode 1 QUIET button Press the QUIET button once again At the same time the mark on the remote controller disappears When the QUIET mode is cancelled the fan speed changes to AUTO You c...

Page 12: ... and heating operation PRESET QUIET SWING TIMER ON FILTER CHK CLOCK OFF CLR SLEEP SET FIX Hi POWER COMFORT SLEEP MODE TEMP FAN 1 PRESET QUIET SWING FIX Hi POWER COMFORT SLEEP MODE TEMP FAN 1 To automatically swing the airflow direction Perform this function when the air conditioner is in operation 1 SWING button Press the SWING button on the remote controller To stop the function press the SWING b...

Page 13: ...T TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 10 6 19 4 2 3 5 7 15 17 16 20 11 14 13 12 8 9 18 AUTO HIGH MED LOW 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control display Displayed when the air conditioner is used under the centra...

Page 14: ... circuit breaker is turned on the remote controller does not accept any commands for approx 1 minute this is not a failure REQUIREMENT When the air conditioner is re powered after it has not been used for a long period turn on the circuit breaker at least 12 hours before starting the air conditioner Start 1 Push button The operation lamp illuminates and the operation starts 2 Select an operation m...

Page 15: ...odes are available Setting of up to 168 hours is enabled Set 1 Push button The timer mode changes with every push of the button and timer display flashes 2 Push to select set time With every push of button the set time increases by 0 5 hr 30 minutes When a time more than 24 hours is set for timer operation timer can be set in increments of 1 hr The maximum set time is 168 hr 7 days The remote cont...

Page 16: ... the power save settings see To configure the power saving mode settings in Power saving mode Even when operation start stop operation mode change or power reset is performed during the power saving mode the power saving mode is retained until the next operation 4 3 1 5 2 UNITNo 1 1 UNIT No 1 2 UNIT No 1 3 UNITNo 1 4 Setting of power level in power saving mode 5 4 Self clean operation mode This fu...

Page 17: ... the Header unit receives SWING signal If the SWING signal is transmitted to follower unit the sound to refuse receiving signal 3 beeps is heard and the follower unit does not receive the signal For FIX operation both Header and follower unit perform the operation by itself When wired remote controller is used airflow direction can be changed on each unit by selecting the indoor unit 4 TIMER lamp ...

Page 18: ... on and off of the cooling operation or fan only operation Increase of using wireless remote controller the fan speed display will indicate AUTO and low speed will be used Set temperature Room temperature Cooling Cooling Cooling Fan only Fan only Time 9 Hints for economical operation Maintain room temperature at comfortable level Clean air filters The clogged air filters impairs the performance of...

Page 19: ...e Check before operation CAUTION Check that the air filters are installed Check that the air discharge or intake of the outdoor unit is not blocked Cleaning the air filter Clean the air filters every 2 weeks If the air filters are covered with dust the performance of the air conditioner will deteriorate Clean the air filters as often as possible 1 If is displayed on the remote controller clean the...

Page 20: ...you purchased it NOTE For environmental conservation it is strongly recommended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratche...

Page 21: ... clothes cigarette cosmetics or other things adhere to the air conditioner The fan continues running even after the unit operation is stopped The fan keeps running to self clean the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the wired remote controller are blinking ...

Page 22: ...blink If the protective device is activated Turn off the circuit breaker and perform a checkup Continued running may cause a malfunction Check whether the air filter is installed If not the heat exchanger may be clogged with dust and water leakage may occur During cooling The air intake or discharge of the outdoor unit is clogged Strong wind continuously blows against the discharge of the outdoor ...

Page 23: ...e quality of preserved materials Do not install the air conditioner over an object that must not get wet Condensation may drop from the indoor unit at a humidity of 80 or more or when the drain port is clogged Do not install the air conditioner in a place where an organic solvent is used Do not install the air conditioner near a door or window subject to humid outside air Condensation may form on ...

Page 24: ...city country 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Amphur Muang Pathumthani 12000 Thailand Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 1111055901 001111055901_01EN book Page 65 Monday September 5 2011 2 23 PM ...

Reviews: