background image

– 17 –

8

How the air conditioner works

Automatic operation

• The air conditioner selects and operates in one of the operating modes of cooling, heating or fan only, depending 

on the room temperature and setting temperature.

• If the AUTO mode is uncomfortable, the desired conditions can be selected manually.

Hi POWER operation

When the Hi POWER button is pushed during cooling, heating or AUTO operation, the air conditioner will start the 
following operation.
• Cooling operation

Performs the cooling operation at 1 °C lower than the setting temperature.
Only when the fan speed before the Hi POWER operation is not high, the fan speed will be increased.

• Heating operation

Performs the heating operation at 2 °C higher than the setting temperature.
Only when the fan speed before the Hi POWER operation is not high, the fan speed will be increased.

COMFORT SLEEP operation

When the COMFORT SLEEP button is pushed during cooling, heating, or AUTO operation, the air conditioner will 
start the OFF timer operation that automatically adjusts the room temperature and the fan speed (expect in DRY, 
FAN ONLY and TIMER mode).
You can select the OFF timer time from four durations (1, 3, 5 or 9 hours).
During group control operation, the set temperature and the fan speed are not automatically adjusted. Only off timer 
function is activated.

QUIET operation

When the QUIET button is pushed during cooling, heating, or AUTO operation, the air conditioner will start the 
following operation.
To operate super low fan speed for quite operation (expect in DRY mode)

DRY operation

This operation is performed when the room temperature is 
higher than the set temperature.
The temperature is regulated while dehumidifying by repeated 
turning on and off of the cooling operation or fan only 
operation.
Increase of using wireless remote controller, the fan speed 
display will indicate AUTO and low speed will be used.

Set temperature

Room

 temp

erature

Cooling

Cooling

Cooling

Fan only

Fan only

Time

9

Hints for economical operation

„

Maintain room temperature at comfortable level

Clean air filters

The clogged air filters impairs the performance of the air conditioner.
Clean them once two weeks.

Do not open doors and windows more often than necessary

To keep cool or warm air in the room, do not open doors and windows more often than necessary.

Window curtains

In cooling, close the curtains to avoid direct sunlight.
In heating, close the curtains to keep the heat in.

Use the timer effectively

Set the timer for the desired operating time.

Get uniform circulation of room air

Adjust air flow direction for even circulation of room air.

10

TEMPORARY operation

In the following cases, the air conditioner can be operating without wireless remote controller with TEMPORARY 
operation button on the indoor unit.
• The battery in the wireless remote controller expired.
• A trouble occurred on the wireless remote controller.
• The wireless remote controller has been lost.
The operation mode is the one last selected. If you want to change it, turn the power off and then on, and push the 
TEMPORARY operation button again.

CAUTION

• If you cannot reach the 

 button by standing on a step-ladder which is lower than 50 cm, contact your dealer or 

qualified service person.

• Continuous pressing of the 

 button for 10 seconds and above will start the forced cooling operation. (This will 

impose burden on the air conditioner. Do not perform this for the purposes other than test run.) In this time all 
indicators of indoor unit go on.

I cannot find the 

remote controller

A TEMPORARY 

operation feature 

is provided!

33-EN

34-EN

+01EN02BODY.fm  Page 17  Monday, September 5, 2011  2:42 PM

Summary of Contents for RAV-SM566KRT-E

Page 1: ...xxxxxxxxxxxxxxxx xx Xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xx Xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xx Xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xx Xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xx Xxxxxxx AIR CONDITIONER SPLIT TYPE Indoor Unit Model name High Wall Type RAV SM566KRT E RAV SM806KRT E Owner s Manual For commercial use 001111055901_01EN book Page 1 Monday September 5 2011 2 23 PM ...

Page 2: ...knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work o...

Page 3: ...th a neighbour install the air conditioner while considering the noise Transportation and storage To transport the air conditioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing cartons for storag...

Page 4: ...ic shocks or other trouble If the fan grille is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified service person 1 to have the repairs done Do not set the circuit breaker to the ON position until the repairs are completed If there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to th...

Page 5: ...tice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Accessory parts 3 Parts name Indoor unit Remote controller Remote controller holder Batteries two SET TIME TIMER SET TEST FILTER RESET CL FAN SAVE SWING FIX VENT MODE UNIT LOUVER 11 10 7 8 9 6 5 3 4 1 2 1 Room temperature sensor 2 Front panel 3 Air intake grille 4 Air filte...

Page 6: ...ems and units When the power is turned on the next time lamp lights up for approximately 1 minute While the above lamp is on all the commands from the remote controller cannot be received However this is not a malfunction or failure When local prohibition is set by the central control from other equipment no signal is received even if the remote controller button is pressed However a signal of STA...

Page 7: ...ESET button Press this button to change the operation mode to the preferred operation mode memorized previously To memorize the operation mode press this button for at least 3 seconds during the preferred operation mode is displayed and the operation mode is memorized 14 SLEEP button Press this button to start the OFF timer operation that automatically adjusts the room temperature and the fan spee...

Page 8: ... controller for more than one month A C L 4 2 Adjusting clock Setting the clock Before you start operating the air conditioner set the clock of the remote controller using the procedures given in this section The clock panel on the remote controller will indicate the time regardless of whether the air conditioner is in use or not Initial setting When batteries are inserted in the remote controller...

Page 9: ...ls can be received by the indoor unit Mounting and removing the remote controller To mount the remote controller hold it parallel to the remote controller holder and push it in fully To remove the remote controller slide the remote controller upwards and out from the holder 7 m 4 4 How to use remote controller Cooling heating fan only operation Start 1 START STOP button Press this button to start ...

Page 10: ...r operation mode the settings are saved in the remote controller Thereafter the air conditioner will start operating under the same conditions when you simply press the ON OFF button of the remote controller If the clock display is flashing you cannot set the timer Follow the instructions in the section Setting the clock and then set the timer Combined timer Setting both ON and OFF timers simultan...

Page 11: ...erating status by automatically setting the fan speed to the lowest speed Setting QUIET mode 1 QUIET button Press the QUIET button after starting any operation At the same time the mark is indicated Cancelling QUIET mode 1 QUIET button Press the QUIET button once again At the same time the mark on the remote controller disappears When the QUIET mode is cancelled the fan speed changes to AUTO You c...

Page 12: ... and heating operation PRESET QUIET SWING TIMER ON FILTER CHK CLOCK OFF CLR SLEEP SET FIX Hi POWER COMFORT SLEEP MODE TEMP FAN 1 PRESET QUIET SWING FIX Hi POWER COMFORT SLEEP MODE TEMP FAN 1 To automatically swing the airflow direction Perform this function when the air conditioner is in operation 1 SWING button Press the SWING button on the remote controller To stop the function press the SWING b...

Page 13: ...T TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 10 6 19 4 2 3 5 7 15 17 16 20 11 14 13 12 8 9 18 AUTO HIGH MED LOW 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control display Displayed when the air conditioner is used under the centra...

Page 14: ... circuit breaker is turned on the remote controller does not accept any commands for approx 1 minute this is not a failure REQUIREMENT When the air conditioner is re powered after it has not been used for a long period turn on the circuit breaker at least 12 hours before starting the air conditioner Start 1 Push button The operation lamp illuminates and the operation starts 2 Select an operation m...

Page 15: ...odes are available Setting of up to 168 hours is enabled Set 1 Push button The timer mode changes with every push of the button and timer display flashes 2 Push to select set time With every push of button the set time increases by 0 5 hr 30 minutes When a time more than 24 hours is set for timer operation timer can be set in increments of 1 hr The maximum set time is 168 hr 7 days The remote cont...

Page 16: ... the power save settings see To configure the power saving mode settings in Power saving mode Even when operation start stop operation mode change or power reset is performed during the power saving mode the power saving mode is retained until the next operation 4 3 1 5 2 UNITNo 1 1 UNIT No 1 2 UNIT No 1 3 UNITNo 1 4 Setting of power level in power saving mode 5 4 Self clean operation mode This fu...

Page 17: ... the Header unit receives SWING signal If the SWING signal is transmitted to follower unit the sound to refuse receiving signal 3 beeps is heard and the follower unit does not receive the signal For FIX operation both Header and follower unit perform the operation by itself When wired remote controller is used airflow direction can be changed on each unit by selecting the indoor unit 4 TIMER lamp ...

Page 18: ... on and off of the cooling operation or fan only operation Increase of using wireless remote controller the fan speed display will indicate AUTO and low speed will be used Set temperature Room temperature Cooling Cooling Cooling Fan only Fan only Time 9 Hints for economical operation Maintain room temperature at comfortable level Clean air filters The clogged air filters impairs the performance of...

Page 19: ...e Check before operation CAUTION Check that the air filters are installed Check that the air discharge or intake of the outdoor unit is not blocked Cleaning the air filter Clean the air filters every 2 weeks If the air filters are covered with dust the performance of the air conditioner will deteriorate Clean the air filters as often as possible 1 If is displayed on the remote controller clean the...

Page 20: ...you purchased it NOTE For environmental conservation it is strongly recommended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratche...

Page 21: ... clothes cigarette cosmetics or other things adhere to the air conditioner The fan continues running even after the unit operation is stopped The fan keeps running to self clean the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the wired remote controller are blinking ...

Page 22: ...blink If the protective device is activated Turn off the circuit breaker and perform a checkup Continued running may cause a malfunction Check whether the air filter is installed If not the heat exchanger may be clogged with dust and water leakage may occur During cooling The air intake or discharge of the outdoor unit is clogged Strong wind continuously blows against the discharge of the outdoor ...

Page 23: ...e quality of preserved materials Do not install the air conditioner over an object that must not get wet Condensation may drop from the indoor unit at a humidity of 80 or more or when the drain port is clogged Do not install the air conditioner in a place where an organic solvent is used Do not install the air conditioner near a door or window subject to humid outside air Condensation may form on ...

Page 24: ...city country 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Amphur Muang Pathumthani 12000 Thailand Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 1111055901 001111055901_01EN book Page 65 Monday September 5 2011 2 23 PM ...