7
1-4. Operation Characteristic Curve
RAV-SP560AT-E, RAV-SP800AT-E
<Cooling>
<Heating>
RAV-SP1100AT-E, RAV-SP1400AT-E
<Cooling>
<Heating>
0
0
20
15
40
60
70
80
100
2
4
6
8
10
12
14
Compressor speed (rps)
Current (A)
• Conditions
Indoor : DB27˚C/WB19˚C
Outdoor : DB35˚C
Air flow : High
Pipe length : 7.5m
230V
0
0
20
15
40
60
80
90 100
2
4
6
8
10
12
16
14
Compressor speed (rps)
Current (A)
• Conditions
Indoor : DB20˚C
Outdoor : DB7˚C/WB6˚C
Air flow : High
Pipe length : 7.5m
230V
0
20
40
60
80
Compressor speed (rps)
0
22
20
18
16
14
12
8
10
6
4
2
Current (A)
Current (A)
0
20
40
60
80
Compressor speed (rps)
0
22
20
18
16
14
12
8
10
6
4
2
• Conditions
Indoor : DB20˚C
Outdoor : DB7˚C/WB6˚C
Air flow : High
Pipe length : 7.5m
230V
RAV-SP800AT-E
RAV-SP800AT-E
RAV-SP560AT-E
RAV-SP560AT-E
RAV-SP1400AT-E
RAV-SP1100AT-E
RAV-SP800AT-E
RAV-SP800AT-E
RAV-SP560AT-E
RAV-SP560AT-E
RAV-SP1400AT-E
RAV-SP1100AT-E
• Conditions
Indoor : DB27˚C/WB19˚C
Outdoor : DB35˚C
Air flow : High
Pipe length : 7.5m
230V