– 7 –
Owner’s Manual
Monitor screen
Check the current usage status.
NOTE
Total running hour
• The operating time is recorded on the remote controller.
• The time is not recorded during self clean operation or fan operation.
Temperature around the outdoor unit
• Displays the temperature around the vent of the outdoor unit.
• The displayed temperature may differ from the actual outdoor temperature.
Filter remaining hour
• The filter remaining hour is not displayed when the filter cleaning timer of the indoor unit is not set.
Others
• The screen returns to the previous display if no operation is performed for 60 seconds.
• When using a Remote sensor or a sensor with Wired remote controller, the setting temperature may not be controlled
accurately due to a difference between the temperature of their sensor and room temperature that can arise due to
radiant heat effects of the wall etc.
Activating the key lock function
1
Push [
MONITOR] button.
The monitor screen appears.
2
Push [
CANCEL] button to return.
(1) Displays the set temperature.
(2) Displays the temperature measured by the room
temperature sensor of the indoor unit.
If the sensor is set to that of the remote controller,
the temperature measured by the remote sensor is
displayed.
(3) Displays the temperature around the vent of the
outdoor unit.
(4) Displays the remaining time until the filter sign lights
up.
(5) Displays the accumulated operating time.
• Push and hold the [
CANCEL] button for more
than 4 seconds to activate the key lock function.
Push and hold the [
CANCEL] button for more
than 4 seconds again to release the key lock.
• “ ” appears on the screen when the button set to be
locked is pushed while the key lock function is
activated.
• Select the buttons to be locked from “Key lock” in
“9. Initial setting" on the menu screen. (page 27)
24
Room A
12:00
Mode
Fan Speed
Cool
Set temp.
24°C
24°C
35°C
2500
10480
Control temp.
Outdoor temp.
Filter remaining hour
Total running hour
Monitor
Return
(1)
(2)
(3)
(4)
(5)
Room A
12:00
Summary of Contents for RB-RWS21-E