7

Adjusting louver direction

• Never move the louver (air direction up / down adjusting plate) which is operated on the remote controller with hands 

except a case of cleaning the louver.

• While the air conditioner is not working, the louver (air direction adjusting plate) is closed automatically.
• During the preparation for heating, the louver is directed upward and it starts swinging after the preparation for 

heating is cancelled though the swing display on the remote controller shows swinging even during this period.

• The louver angle does not change immediately after the FIX button is pushed. Check the louver status, and push 

FIX button after a while.

To set louver direction

Push FIX   button during operation. Louver direction 
changes each time you push the button.

To start swinging

Push SWING 

 button on the remote controller. Louver 

swinging appears on the display and louver direction 
automatically changes up and down.

Heating mode

Keep the louver pointed downward so that discharged hot 
air reaches the floor.

Cooling / dry mode

Keep the louver pointed upward. Otherwise, dew drop 
may form around the discharge port and drop from the 
unit.

To stop swinging

Push SWING 

 button once again while the louver is 

swinging. The louver can be stopped at a desired 
position.

CAUTION

• The louver angle does not change if the FIX button 

is pushed during SWING operation. Stop the SWING 
operation before changing the louver angle.

• Do not operate the air conditioner for long hours with 

the airflow direction set downward during the cooling 
or dry operation.
Otherwise, condensation may occur on the surface 
of the vertical airflow louver and cause dew dripping.

8

Mounting remote controller holder

• Direct the transmitter of the remote controller toward 

the signal receiving unit.
When the signal is normally received, “Pi” sound is 
heard once.
(“Pi, pi” sounds are heard only when the operation has 
started.)

• The standard distance for signal reception is 

approximately 26'2" (8 m) vertically against the signal 
receiving unit.
The distance differs a little according to the capacity of 
the battery or other factor.

• Be careful there is not something to block the signal 

between the signal receiving unit and the remote 
controller.

• Do not put the remote controller on the place exposed 

to the direct sunlight or air from the air conditioner or 
near the stove, etc.

• Do not drop, throw, or clean with water the remote 

controller.

• The signal may not be accepted in a room where the 

electronic instantaneous-ON type or inverter type 
fluorescent light is set. For details, contact the shop 
which you purchased the air conditioner.

To use the remote controller 
setting to wall

Check a signal is received correctly by pushing 

 

START/STOP button at the position to be fixed.

Mounting screw

Remote controller holder

Setting method of remote 
controller

Put on.

1

Push.

2

12-EN

+EH99950501.BOOK  Page 12  Thursday, June 18, 2015  10:57 AM

Summary of Contents for RBC-AX32UW-UL

Page 1: ...ss remote controller kit Model name RBC AX32U W UL Generic model name Wireless remote controller model name RBC AX32U W UL WH L15SE Signal receiving unit model name SX W3BQ AIR CONDITIONER SPLIT TYPE Owner s Manual EH99950501 BOOK Page 1 Thursday June 18 2015 10 57 AM ...

Page 2: ...ler 13 10 Before asking for repair work 14 Thank you very much for purchasing TOSHIBA Carrier Remote controller for Air Conditioner Please read this owner s manual carefully before using your Remote controller for Air Conditioner Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner ...

Page 3: ...oner is continuously operated with something abnormal it may cause machine failure electric shock fire or other trouble Reinstallation and repair Do not repair any unit by yourself Whenever the air conditioner needs repair make sure to ask the dealer to do it If it is repaired imperfectly it may cause electric shock fire or other trouble When reinstalling the air conditioner contact with the deale...

Page 4: ...er will indicate the time regardless of whether the air conditioner is in use or not Initial setting When batteries are inserted in the remote controller the clock panel will indicate AM 0 00 and will flash 1 TIMER or button Push the TIMER or button to set the current time Each push of the TIMER button changes the time in one minute steps Pushing the TIMER button continually changes the time in te...

Page 5: ...ush the SWING button to stop the louver swinging A receiving beep is heard 7 Set louver button FIX Push this button to adjust the airflow direction A receiving beep is heard It cannot be operated by holding down the button Push the button with some interval 8 Off timer button OFF Push this button to set the OFF timer 9 On timer button ON Push this button to set the ON timer 10Reserve button SET Pu...

Page 6: ...smission mark This transmission mark indicates when the remote controller transmits signals to the indoor unit 2 Mode display Indicates the current operation mode A Auto changeover control Cool Dry Heat Fan only 3 Temperature display Indicates the temperature setting 62 F to 86 F When you set the operating mode to Fan only no temperature setting is indicated 4 FAN speed display Indicates the selec...

Page 7: ... signal sent from the remote controller is received 3 Display lamp One of displays flashed while an error occurs When the display lamp flashes refer to Before asking for repair work 4 lamp Green This lamp illuminates when unit is on 5 lamp Green This lamp illuminates while the timer is reserved 6 lamp Orange In heating operation this lamp illuminates in the following cases The operation has starte...

Page 8: ...tion auto changeover Start 1 START STOP button Push this button to start the air conditioner 2 Mode select button MODE Select A 3 Temperature button Set the desired temperature 4 Fan speed button FAN Set a desired fan speed Five patterns are displayed but LOW is equal to LOW and MED to MED The OPERATION lamp green on the display lamp of the signal receiving unit lights The operating mode is select...

Page 9: ...en Auto changeover control mode is selected the air conditioner does not automatically control the room temperature Quiet operation The QUIET mode provides quiet operating status by automatically setting the fan speed to the lowest speed Setting QUIET mode 1 QUIET button Push the QUIET button after starting any operation At the same time the mark is indicated Cancelling QUIET mode 1 QUIET button P...

Page 10: ...is a OFF timer operation with automatic temperature and fan speed adjustment 1 Push the COMFORT SLEEP button Select 1 3 5 or 9 hours for the OFF timer operation CAUTION The COMFORT SLEEP mode is not enabled in the DRY or FAN ONLY operation When Auto changeover control mode is selected the air conditioner does not automatically control the room temperature Sleep timer operation To start the sleep t...

Page 11: ...time lag of up to 15minutes will occur If you do not push the SET button within 30 seconds after setting the time the setting will be cancelled Once you select the timer operation mode the settings are saved in the remote controller Thereafter the air conditioner will start operating under the same conditions when you simply push the ON OFF button of the remote controller If the clock display is f...

Page 12: ...mer simultaneously and activate every day This feature is useful when you want to use combined timer at the same time every day Setting combined TIMER 1 Push the ON TIMER button to adjust the ON timer 2 Push the OFF TIMER button to adjust the OFF timer 3 Push the SET button 4 After step 3 an arrow mark or flashes for about 3 seconds and during this flashing push the SET button During the every day...

Page 13: ...g SWING operation Stop the SWING operation before changing the louver angle Do not operate the air conditioner for long hours with the airflow direction set downward during the cooling or dry operation Otherwise condensation may occur on the surface of the vertical airflow louver and cause dew dripping 8 Mounting remote controller holder Direct the transmitter of the remote controller toward the s...

Page 14: ...e controllers do not display A The factory default of the wireless remote controllers is A A B selection can be set with signal receiving unit For the further details refer to the installation manual 9 Operating air conditioner without remote controller In the following cases the air conditioner can be operate without remote controller with temporary operation button on the signal receiving unit T...

Page 15: ...e air conditioner is in the ON timer operation Cancel the timer operation The batteries of the remote controller have been exhausted Replace the batteries The LEDs on the signal receiving unit are not in normal state or operation mode is not correct Change the operation mode Is not the state of the display lamp Disagreement of cool and heat or A Automatic operation Change the operation mode Dual s...

Page 16: ...EH99950501 EH99950501 BOOK Page 31 Thursday June 18 2015 10 57 AM ...

Reviews: