background image

– 11 –

ON timer —> OFF timer

 

(Stop —> Operation —> Stop)

You can use this setting to start the air conditioner when 
you wake up and stop it when you leave the house.
Example:
To start the air conditioner next morning and stop it.

Setting combined TIMER

1. Push the ON TIMER   button to adjust the 

ON timer.

2. Push the OFF TIMER   button to adjust the 

OFF timer.

3. Push the SET 

 button.

• Either ON or OFF timer function which is closer to the 

current time, is activated first.

• If the same time is set for both ON and OFF timers, no 

timer operation is performed.

 

Also, the air conditioner may stop operating.

Every day combined timer (setting both 
ON and OFF timer simultaneously and 
activate every day.)

This feature is useful when you want to use combined 
timer at the same time every day.

Setting combined TIMER

1. Push the ON TIMER   button to adjust the 

ON timer.

2. Push the OFF TIMER   button to adjust the 

OFF timer.

3. Push the SET 

 button.

4. After step 3, an arrow mark (  or  ) flashes 

for about 3 seconds and during this flashing, 
push the SET 

 button.

During the every day timer is activating, both arrows (

) are indicated.

Cancel the timer operation

Push the CLR 

 button.

Clock display

During the TIMER operation (ON-OFF, OFF-ON, OFF 
timer) clock display is disappeared so as to show the 
setting time. To see the present time, push SET button 
briefly and the present time is displayed about 3 seconds.

Operation

Stop

Stop

ON

OFF

SET

ON

OFF

SET

SET

CLR

11-EN

Summary of Contents for RBC-AX33CE

Page 1: ...glish Wireless remote controller kit Model name RBC AX33CE Generic model name Wireless remote controller model name RBC AX33CE WH L11SE Signal receiving unit model name SX W6NE AIR CONDITIONER SPLIT TYPE Owner s Manual ...

Page 2: ...ditioner without remote controller 13 10 Before asking for repair work 14 Thank you very much for purchasing TOSHIBA Remote controller for Air Conditioner Please read this owner s manual carefully before using your Remote controller for Air Conditioner Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the...

Page 3: ...aler If the air conditioner is continuously operated with something abnormal it may cause machine failure electric shock fire or other trouble Reinstallation and repair Do not repair any unit by yourself Whenever the air conditioner needs repair make sure to ask the dealer to do it If it is repaired imperfectly it may cause electric shock fire or other trouble When reinstalling the air conditioner...

Page 4: ...ime regardless of whether the air conditioner is in use or not Initial setting When batteries are inserted in the remote controller the clock panel will indicate AM 0 00 and will flash 1 TIMER or button Push the TIMER or button to set the current time Each push of the TIMER button changes the time in one minute steps Pushing the TIMER button continually changes the time in ten minute steps 2 SET b...

Page 5: ...e louver A receiving beep is heard Push the SWING button to stop the louver swinging A receiving beep is heard 7 Set louver button FIX Push this button to adjust the airflow direction A receiving beep is heard It cannot be operated by holding down the button Push the button with some interval 8 Off timer button OFF Push this button to set the OFF timer 9 On timer button ON Push this button to set ...

Page 6: ...nals to the indoor unit 2 Mode display Indicates the current operation mode A Auto changeover control Cool Dry Heat Fan only 3 Temperature display Indicates the temperature setting 17 C to 30 C When you set the operating mode to Fan only no temperature setting is indicated 4 FAN speed display Indicates the selected fan speed AUTO or one of five fan speed levels LOW LOW MED MED HIGH can be indicate...

Page 7: ... page 13 2 Signal receiving part The signal sent from the remote controller is received 3 Display lamp One of displays flashed while a trouble occurs When the display lamp flashes refer to Before asking for repair work 4 lamp Green This lamp goes on during operation 5 lamp Green This lamp goes on while the timer is reserved 6 lamp Orange In heating operation this lamp in the following cases The op...

Page 8: ...matic operation auto changeover Start 1 START STOP button Push this button to start the air conditioner 2 Mode select button MODE Select A 3 Temperature button Set the desired temperature 4 Fan speed button FAN Set a desired fan speed Five patterns are displayed but LOW is equal to LOW and MED to MED The OPERATION lamp green on the display lamp of the signal receiving unit lights The operating mod...

Page 9: ...ode is selected the air conditioner does not automatically control the room temperature Quiet operation The QUIET mode provides quiet operating status by automatically setting the fan speed to the lowest speed Setting QUIET mode 1 QUIET button Push the QUIET button after starting any operation At the same time the mark is indicated Cancelling QUIET mode 1 QUIET button Push the QUIET button once ag...

Page 10: ... temperature and fan speed adjustment 1 Push the COMFORT SLEEP button Select 1 3 5 or 9 hours for the OFF timer operation CAUTION The COMFORT SLEEP mode is not enabled in the DRY or FAN ONLY operation When Auto changeover control mode is selected the air conditioner does not automatically control the room temperature Sleep timer operation To start the sleep timer OFF timer operation 1 Push the SLE...

Page 11: ...o 15 minutes will occur If you do not push the SET button within 30 seconds after setting the time the setting will be cancelled Once you select the timer operation mode the settings are saved in the remote controller Thereafter the air conditioner will start operating under the same conditions when you simply push the ON OFF button of the remote controller If the clock display is flashing you can...

Page 12: ... setting both ON and OFF timer simultaneously and activate every day This feature is useful when you want to use combined timer at the same time every day Setting combined TIMER 1 Push the ON TIMER button to adjust the ON timer 2 Push the OFF TIMER button to adjust the OFF timer 3 Push the SET button 4 After step 3 an arrow mark or flashes for about 3 seconds and during this flashing push the SET ...

Page 13: ...the FIX button is pushed during SWING operation Stop the SWING operation before changing the louver angle Do not operate the air conditioner for long hours with the airflow direction set downward during the cooling or dry operation Otherwise condensation may occur on the surface of the vertical airflow louver and cause dew dripping 8 Mounting remote controller holder Direct the transmitter of the ...

Page 14: ... to be A The wireless remote controllers do not display A The factory default of the wireless remote controllers is A A B selection can be set with signal receiving unit For the further details refer to the installation manual 9 Operating air conditioner without remote controller In the following cases the air conditioner can be operate without remote controller with temporary operation button on ...

Page 15: ...emote controller again The power switch is not turned on Turn on the power switch if it is off The air conditioner is in the ON timer operation Cancel the timer operation The batteries of the remote controller have been exhausted Replace the batteries The LEDs on the signal receiving unit are not in normal state or operation mode is not correct Change the operation mode Is not the sate of the disp...

Page 16: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Reviews: