Model name

RDA-S

2401HA / D

037-ME

2401HA / D

055-ME

2401HA / D

075-ME

3001HA / D

037-ME

3001HA / D

055-ME

3001HA / D

075-ME

Cooling capacity                              (*1)

kW

66.3

67.2

67.9

82.1

84.0

84.0

Cooling capacity                              (*2)

kW

48.8

49.5

50.0

55.1

56.4

56.4

Heating capacity

kW

74.3

75.0

75.3

93.0

94.5

94.5

Electrical 
characteristics

Power supply

Voltage

3 phase 4wire 50 / 60 Hz 400 V

Running 
current

50 Hz

A

6.42

9.00

11.00

6.56

9.04

10.9

60 Hz

A

6.34

9.12

12.35

6.47

9.37

11.5

Power 
consumption

50 Hz

kW

3.20

4.09

4.97

3.32

4.13

4.90

60 Hz

kW

3.61

5.07

7.08

3.70

5.25

6.49

Starting 
current

50 Hz

A

67.0

100

132

67.0

100

132

60 Hz

A

59.0

83.0

109

59.0

83.0

109

Appearance

W: Silky shade (1Y 8.5 / 0.5)

Dimension

Height

mm

2300

Width

mm

1800

Depth

mm

820

Total weight

kg

410

430

440

410

430

440

Heat exchanger

Copper tubes, Aluminum plate fins

Soundproof / Heat-insulating material

Polyolefin form insulation

Fan unit

Fan

Multi blades centrifugal; Belt drive

Standard air flow   (*3)

m

3

/h

10800

12600

13800

12600

15300

15300

Air flow 
limit

Lower

m

3

/h

9000

9600

Upper

m

3

/h

18000

18600

External 
static 
pressure

50 Hz

Pa

256

406

475

130

154

292

60 Hz

424

654

768

276

354

542

Motor

W

3700

5500

7500

3700

5500

7500

Air Filter

none

Controller

Remote controller (Optional accessory)

Connecting 
pipe

Gas side

mm

Ø 34.9

Liquid side

mm

Ø 19.1

Drain port

Outer dim.

mm

VP30A (Ø 38)

Inner dim.

mm

VP25A (Ø 32)

Sound pressure level       (*4)

50 Hz

dB(A)

58.7

63.1

64.9

55.7

58.6

62.3

60 Hz

dB(A)

62.4

66.7

68.5

60.4

63.6

66.5

(*1): Rated conditions 

Cooling: Indoor 27 degC Dry Bulb / 19 degC Wet Bulb, Outdoor 35 degC Dry Bulb.

 

 

 

Heating: Indoor 20 degC Dry Bulb, Outdoor 7 degC Dry Bulb / 6 degC Wet Bulb.

 

 

 

Based on equivalent piping length of 7.5 m and piping height difference of 0 m.

(*2): Rated conditions  

Cooling: Indoor 27 degC Dry Bulb / 19 degC Wet Bulb, Outdoor 46 degC Dry Bulb.

 

 

 

Based on equivalent piping length of 7.5 m and piping height difference of 0 m.

(*3): As air volume is fixed, by remote controller, air volume cannot be changed. When required high static pressure and 
 

air volume change, a pulley change is requested.

(*4): The sound levels are measured in an anechoic chamber. Normally, the sound level measured in the actual operating 
 

environment become bigger than the rated figures due to the effects of external sound.

Specifications (continued)

Summary of Contents for RDA-S 2001HA / D015-ME

Page 1: ......

Page 2: ...ilure to adhere to the directions in the warning could result in serious bodily harm 1 or loss of life if the product is handled improperly This indicates that failure to adhere to the directions in the caution could result in serious bodily injury 2 or damage to property 3 if the product is handled improperly 1 Serious bodily harm indicates loss of eyesight injury burns electric shock bone fractu...

Page 3: ...r original retailer Continuing operation while the problem remains may cause fire electric shock or malfunction If the air conditioner doesn t cool or heat up the air it may be due to a refrigerant leak so please contact your original retailer If repairs involve refrigerant recharge check the details of the repairs with the service person The refrigerant used in the air conditioner is quite harmle...

Page 4: ...s precision machinery or artwork Doing so may cause a decrease in quality When cleaning the unit stop operation and turn off the power Use only fuses with the correct capacity The internal fans rotate very fast and may cause an injury For cleaning please contact your original retailer Cleaning the unit incorrectly may lead to the resin components becoming damaged or the insulation resistance of th...

Page 5: ...4 Component Names Indoor Unit Duct type Air discharge Drain Pan Metal fitting Metal fitting Earth screw Air Inlet ...

Page 6: ...DLU FRQGLWLRQHU RQ RII DOVR WXUQV WKH YHQWLODWRU RQ RII 1R YHQWLODWRU LV FRQQHFWHG LI DSSHDUV RQ WKH UHPRWH FRQWURO GLVSOD DIWHU SUHVVLQJ WKH 9 17 EXWWRQ SWING FIX button Controls the louver angle or activates DXWRPDWLF VZLQJ RI WKH ORXYHUV Ɣ7KLV IXQFWLRQ LV QRW DYDLODEOH IRU WKLV XQLW UNIT button I WZR RU PRUH LQGRRU XQLWV DUH FRQWUROOHG E RQH UHPRWH FRQWURO XVH WKLV EXWWRQ WR VHOHFW a unit to ad...

Page 7: ...ner s Manual for the central remote control No function indicator Displayed when there is no function available for the pressed button Temperature setting indicator Indicates the temperature setting Pre heat indicator Displayed when heating is starting or while defrosting While the indicator is displayed the indoor fan is stopped or the air circulation is running Power saving display Displayed dur...

Page 8: ...emperature However for floor types direct type duct type the air volume does not change after room temperature has reached the set temperature Running starts in approximately one minute When cooling Turn on the circuit breaker and leakage breaker When turned on the separation line appears and blinks on the remote control display The remote control will not work for about one minute after turning o...

Page 9: ... 2 3 Push the button disappears the time indication is displayed and or blinks When using the ON timer all indications other than the time and turn off No indication Timer function is deactivated OFF timer Repeat OFF timer ON timer and the time indicator blink The time setting decreases in 0 5 hour 30 minute decrements 0 5 hours to 23 5 hours or 1 hour decrements 24 hours to 168 hours each time yo...

Page 10: ...od drainage Make sure the air filter is attached to the indoor unit If not dust may accumulate on the heat exchanger etc in the air conditioner and cause water leakages Keep a distance of at least 1 m between the air conditioner remote control and TVs or radios Failure to do so may cause visual disturbance or noise Leave a distance of at least 1 5 m between the air outlet and fire alarms When a fi...

Page 11: ...ed units While other indoor units operate the fans on indoor units in stand by mode rotate for several minutes approximately once per hour to protect the machines Cooling Heating operations of a package air conditioner Standard type Each unit can be controlled individually However indoor units connected to the same outdoor unit cannot perform cooling and heating simultaneously When you attempt sim...

Page 12: ...ooling season Clean the drain pan Maintenance Be sure to turn off the main power switch prior to the maintenance Caution Periodical check up After being used for a long period of time the parts may deteriorate or malfunction or the drainage may worsen due to heat moisture dust or general usage In addition to the normal maintenance it is recommended that you have a check up charges apply performed ...

Page 13: ...lose windows and doors Do not let cooled heated air escape from the room Do not use other heating equipment next to the indoor unit The heat from the other heating equipment may cause the intake grill to warp and change shape Do not put anything near the air inlet and air outlet Performance may be lowered or operation may stop Do not cool heat too much It is bad for your health In particular take ...

Page 14: ...se when it is turned on The expansion valve makes this sound during operation when the power is turned on The display blurs when you touch the remote control LCD The LCD may become temporarily blurred due to static electricity The unit starts or stops automatically Has an ON or OFF timer been set When the air conditioner won t turn on Has there been a power failure Is the power turned off Has the ...

Page 15: ...SET and TEST buttons at the same time for 4 seconds or more brings up the following display Service check is displayed to indicate that the unit has entered the problem history mode The CODE No section displays 01 Order of problem history Check code is displayed UNIT No indicates No of the indoor unit where an error has occurred Each time the buttons used to set the temperature are pushed the prob...

Page 16: ...00 External static pressure 50 Hz Pa 223 211 457 664 538 60 Hz 338 361 694 944 845 Motor W 1500 2200 3700 5500 7500 Air Filter none Controller Remote controller Optional accessory Connecting pipe Gas side mm Ø 28 6 Liquid side mm Ø 15 9 Drain port Outer dim mm VP30A Ø 38 Inner dim mm VP25A Ø 32 Sound pressure level 4 50 Hz dB A 54 7 56 4 62 0 64 9 65 9 60 Hz dB A 57 9 60 2 65 2 67 7 69 2 1 Rated c...

Page 17: ...rnal static pressure 50 Hz Pa 120 56 274 498 408 60 Hz 252 250 499 775 711 Motor W 1500 2200 3700 5500 7500 Air Filter none Controller Remote controller Optional accessory Connecting pipe Gas side mm Ø 28 6 Liquid side mm Ø 15 9 Drain port Outer dim mm VP30A Ø 38 Inner dim mm VP25A Ø 32 Sound pressure level 4 50 Hz dB A 51 5 50 0 59 7 63 9 64 4 60 Hz dB A 56 5 58 1 63 9 67 2 68 3 1 Rated condition...

Page 18: ... 18000 18600 External static pressure 50 Hz Pa 256 406 475 130 154 292 60 Hz 424 654 768 276 354 542 Motor W 3700 5500 7500 3700 5500 7500 Air Filter none Controller Remote controller Optional accessory Connecting pipe Gas side mm Ø 34 9 Liquid side mm Ø 19 1 Drain port Outer dim mm VP30A Ø 38 Inner dim mm VP25A Ø 32 Sound pressure level 4 50 Hz dB A 58 7 63 1 64 9 55 7 58 6 62 3 60 Hz dB A 62 4 6...

Page 19: ...18 Notes ...

Reviews: