TOSHIBA
40
Operations
1) Connect the cables to the motor and power source.
2) Turn the built-in pontentiometer fully
counterclock-wise.
3) Turn on the power.
4)
0.0
is displayed on the display unit.
5) Press the RUN key.
6) Turn the built-in pontentiometer clockwise
gradually.
7) The RUN lamp goes on. The motor starts and its
rotation speed increases gradually.
8) The operation frequency is displayed on the
display unit.
9) To stop the motor, press the STOP key.
10) The motor speed decreases according to the
deceleration pattern.
11) The RUN lamp goes out.
(2) (6)
(7) (11)
(4) (8)
Operation with Built-in Potentiometer and RUN and STOP Keys
Review all operating precautions on page 11 before operating this drive.
C A U T I O N
(9)
(5)