TOSHIBA
41
Operations (cont'd)
1) Connect the cables to the motor and power
source. (See “CONNECTING OF THE MAIN
CIRCUITS.”)
2) Connect a start/stop switch between the control
terminal F and CC (for forward rotation) or
between R and CC (for reverse rotation).
(See “CONNECTING THE CONTROL WIRES.”)
3) Turn the built-in pontentiometer
fully counterclockwise.
4) Turn on the power.
5) Set the parameters
COO8
to
0
and
FOO8
to
2
. (See “Setting the
Starting and Stopping Methods”
and “Setting the Frequency
Command Method”.)
6)
0.0
is displayed on the display unit.
7) Turn on the forward or reverse
switch.
8) Turn the built-in pontentiometer
clockwise gradually.
9) The RUN lamp goes on. The motor
starts and its rotation speed increases
gradually.
10) The operation frequency is displayed
on the display unit.
11) To stop operation, turn off the forward
or reverse switch.
12) The motor speed decreases according
to the deceleration pattern.
13) The RUN lamp goes out.
(3) (8)
(9) (13)
(6) (10)
Operation with Built-in Potentiometer and External Start Signal
(2) (7) (11)
Forward
Error reset
Reverse