Troubleshooting Procedures
2-16 [CONFIDENTIAL] TECRA M11/Satellite Pro S500M Series Maintenance Manual (960-813)
Check 1 Convert the DC IN icon blink pattern into the hexadecimal error code and compare
it to the tables below. Then go to Check 2.
Table 2-3 Error code
Error code
Where error occurs
1*h
DC Power (AC Adapter)
2*h Main
battery
3:h 2nd
battery
4*h
S3V output
5*h E5V
output
6*h
E3V output
7*h IGD-PGV
output
8*h
1R5-B1V output
9*h PPV
output
A*h 1R05-E1V
output
B*h IGD-PGV
output
C*h PTV
output
D*h PTV
output
E*h -
F*h -
DC power supply (AC adapter)
Error code Meaning
10h
AC Adapter output voltage is over 16.5V.
11h
Common Dock output voltage is over 16.5V..
12h
Current from the DC power supply is over 4.95A.
13h
Current from the DC power supply is over 0.5A when there is no load.
14h
The compensation value of [0A] is not within the limits from design data (±
481mA).