Replacement Procedures
Satellite U400/Satellite Pro U400/PORTEGE M800
Maintenance Manual 49
Installing the LCD unit/FL Inverter
The following describes the procedure
of
installing the LCD unit and FL inverter.
1.
Install the LCD supports (LCD unit side) to the LCD and secure them with the
following
screws
.
•
M2.0
×
2.5 BINK screw
x4
2.
Stand the
LCD unit
on the display cover and connect the
LCD harness
to the
connector on the back of LCD.
3.
Stick the
conductive tape
on the connector of LCD harness.
4.
Secure the LCD unit with the following
screws
.
•
M2.5
×
4.0
BINK
screw
x2
5.
Connect
LCD harnesses
to the connector
CN1
of the FL inverter.
CAUTION: Be careful not to connect the LCD harnesses to the wrong connectors of FL
inverter.
6.
Connect
HV harnesses
to the connector
CN2
of the FL inverter.
7.
Install the
display mask
while fitting the latches.
8.
Secure the display mask with following
screws
M2.5
×
5.0 BIND screw X6
9.
Cover screws with Screw rubber cover X6
NOTE: When installing the display mask, make sure there is no gap between the display
mask and the display cover.
Summary of Contents for Satellite Pro U400 Series
Page 110: ...Test Program for Field Satellite U400 and Satellite Pro U400 Tests and Diagnostics Manual 17 ...
Page 168: ...Replacement Procedures Satellite U400 Satellite Pro U400 PORTEGE M800 Maintenance Manual 4 iv ...
Page 276: ...Pin Assignment 36 Satellite U400 Satellite Pro U400 PORTEGE M800 Maintenance Manual ...
Page 302: ...Wiring Diagrams F 2 Satellite U400 Satellite Pro U400 PORTEGE M800 Maintenance Manual ...