Chapter2 Troubleshooting Procedures
2-8 Satellite U400/Satellite Pro U400/PORTEGE M800
Maintenance Manual
Table 2-2 DC IN icon
DC IN icon
Power supply status
Lights blue or white
DC power is being supplied from the AC adapter.
Blinks orange
Power supply malfunction
*1
Doesn’t light
Any condition other than those above.
*1 when the power supply controller detects a malfunction, the DC IN icon blinks
orange. It shows an error code.
When the icon is blinking, perform the following procedure.
1.
Remove the battery pack and the AC adapter.
2.
Re-attach the battery pack and the AC adapter.
If the icon is still blinking after the operation above, check the followings:
Check 1 If the DC IN icon blinks orange, go to Procedure 2.
Check 2 If the DC IN icon does not light, go to Procedure 3.
Check 3 If the battery icon does not light orange or green, go to Procedure 4.
NOTE: Use a supplied AC adapter.
Procedure 2
Error Code Check
Device
Name
Error Code
Error Status Name
(Common)
FF
Data Compare Error
Memory
2
Protected Mode Not Changed
??
Other
Error
FDD
1
Bad Command Error
2
Address Mark Not Found
3
Write
Protected
4
Record Not Found
6
Media Change Line Error
8
DMA Overrun Error
9
DMA Boundary Error
0C
Select Media Error
10
CRC
Error
20
FDC
Error
40
Seek
Error
Summary of Contents for Satellite Pro U400 Series
Page 110: ...Test Program for Field Satellite U400 and Satellite Pro U400 Tests and Diagnostics Manual 17 ...
Page 168: ...Replacement Procedures Satellite U400 Satellite Pro U400 PORTEGE M800 Maintenance Manual 4 iv ...
Page 276: ...Pin Assignment 36 Satellite U400 Satellite Pro U400 PORTEGE M800 Maintenance Manual ...
Page 302: ...Wiring Diagrams F 2 Satellite U400 Satellite Pro U400 PORTEGE M800 Maintenance Manual ...