Chapter2 Troubleshooting Procedures
Satellite U400/Satellite Pro U400/PORTEGE M800
Maintenance Manual 2-15
Check 3
The IRT checks the system board. When the IRT detects an error, the system
stops or an error message appears.
If one of the following error messages (1) through (17), (24) or (25) is displayed,
go to Procedure 4.
If error message (18) is displayed, go to the Keyboard Troubleshooting
Procedures.
If error message (19), (20) or (21) is displayed, go to the 2.5” HDD
Troubleshooting Procedures.
If error message (22) or (23) is displayed, go to the USB FDD Troubleshooting
Procedures.
(1)
PIT ERROR
(2)
MEMORY REFRESH ERROR
(3)
TIMER CH.2 OUT ERROR
(4)
CMOS CHECKSUM ERROR
(5)
CMOS BAD BATTERY ERROR
(6)
FIRST 64KB MEMORY ERROR
(7)
FIRST 64KB MEMORY PARITY ERROR
(8)
VRAM ERROR
(9)
SYSTEM MEMORY ERROR
(10)
SYSTEM MEMORY PARITY ERROR
(11)
EXTENDED MEMORY ERROR
(12)
EXTENDED MEMORY PARITY ERROR
(13)
DMA PAGE REGISTER ERROR
(14)
DMAC #1 ERROR
(15)
DMAC #2 ERROR
(16)
PIC #1 ERROR
(17)
PIC #2 ERROR
(18)
KBC ERROR
(19)
HDC ERROR
(20)
HDD #0 ERROR
(21)
HDD #1 ERROR
(22)
NO FDD ERROR
(23)
FDC ERROR
(24)
TIMER INTERRUPT ERROR
(25)
RTC UPDATE ERROR
Summary of Contents for Satellite Pro U400 Series
Page 110: ...Test Program for Field Satellite U400 and Satellite Pro U400 Tests and Diagnostics Manual 17 ...
Page 168: ...Replacement Procedures Satellite U400 Satellite Pro U400 PORTEGE M800 Maintenance Manual 4 iv ...
Page 276: ...Pin Assignment 36 Satellite U400 Satellite Pro U400 PORTEGE M800 Maintenance Manual ...
Page 302: ...Wiring Diagrams F 2 Satellite U400 Satellite Pro U400 PORTEGE M800 Maintenance Manual ...