DK424 Installation
Cabinet Floor Mounting
Strata DK I&M 6/00
5-21
DK424 Installa
tion
Cabinet Floor Mounting
One or Two Cabinets
1. Remove front, side, and top covers from cabinet(s) (
). Remove plastic locating parts
from all cabinet back covers using a Phillips screwdriver (
).
2. Make sure that cabinet power supplies (RPSU280) are installed per
3. If installing just one cabinet, install the RFMF fixtures on each side of the bottom of the
) and place the cabinet where it should be installed (go to Step 6).
4. If installing two cabinets, install a floor fixture (RFMF1) on each side of the cabinet that will
be the bottom cabinet, making sure that the fixture is inside of the cabinet edge.
5. If installing two cabinets:
♦
Set the bottom cabinet on the floor or mount surface, then set the top cabinet on the bottom
cabinet.
♦
Fasten the two cabinets together with the four screws provided: (two screws at front “A”
and two at back “B” of cabinet. Place cabinet where it should be installed.
♦
Connect the Expansion Cabinet data cable to the “CAB. 2” data cable connector on the
Base Cabinet (
).
...or if installing a Remote Expansion Cabinet: see details in
6. Install ground wiring, AC and reserve power cabling, and PCB cabling per the
“Recommended Installation Sequence” on Page 5-7
7. Fill out cabinet/slot identification labels on cabinet(s) (
8. Reinstall covers on to cabinet(s).
Three or More Cabinets
This section shows you how to mount three or more cabinets to a concrete, wood or computer
room floor. Use the General Steps for all of these methods first, then the specific steps that follow
for each method.
1. Make sure that cabinet power supplies (RPSU280) are installed per
2. Remove front, side, and top covers from all cabinets (
Remove plastic locating parts from all cabinet back covers using Phillips screwdriver (
3. Install a floor fixture (RFMF1) on each side of the bottom cabinet. (Make sure that the fixture
is inside of the cabinet edge. For Steps 3~10, see
4. Place cabinet two on top of the bottom cabinet and connect them together at points A and B
with the screws provided.
5. Place cabinet three on top of cabinet 2 and connect them together at points A and B with the
screws provided.
6. If installing more than three cabinets, install wall brackets (RWBF1) on the top of cabinet 3.
Position the 3 cabinets parallel to the wall (2 inches from the wall) and secure the wall
brackets to the wall with customer-provided wood screws and wall anchors as required.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...