DK424 Installation
Reserve Power Installation
Strata DK I&M 6/00
5-41
DK424 Installa
tion
1. When floor mounting the DK424, the batteries must be installed by a licensed electrician per local electric code using conduit.
(See
and
DKSUE424.)
2. RBTC1A-2M cable current ratings: discharge, 12 amps max./charge, 3.9 amps max.
3. PBTC-3M and RBTC1A-15M cable current ratings: discharge, 4.9 amps max./charge 0.6 amps max.
4. Batteries should be installed in a customer-supplied commercial battery box or enclosed rack.
Figure 5-25 Battery Wiring Diagram (Two or Four Batteries) Wall Mount Only
Notes
●
PBTC-3m cables are used for one or two cabinets installations (see
RBTC1A-2M cables are used for three or more cabinet installations (DKSUE424).
Important!
Since these cables are not UL listed, a licensed electrician should install them.
Cables connecting to batteries must be 16 AWG minimum.
To RPSU280 “BATT”
Connectors (6 max)
White Wire
Black Wire
2-Batteries/1~7 Cabinets (with RBDB2)
1
12 Volt4
Batteries
80 AMP/
HR Each
RBTC1A-1.5M Cables (6-max)
Cable for 7th cabinet
(order number RC7C1A-1.7M)
12A Fuse
4-Batteries/1~7 Cabinets (with RBDB2)
RBTC1A-2M
Cable (6.5 ft)
2
To RPSU280 “BATT”
Connectors (6 max)
2-Batteries/1-Cabinet (without RBDB)
12 Volt4
Batteries
80 AMP/
HR Each
12 Volt4
Batteries
80 AMP/
HR Each
10A Fuse
PBTC-3M Cables (9 ft)
–
+
RPSU 280 BATT
Cconnnector
RPSU 280 BATT
connnector
RPSU 280 BATT
connnector
RPSU 280 BATT
connnector
RPSU 280 BATT
connnector
4-Batteries/2-Cabinets (without RBDB)
2-Batteries/2-Cabinets (without RBDB)
10A Fuse
10A Fuse
PBTC-3M Cables (9 ft)3
Expansion Cabinet
Base Cabinet
Base Cabinet
Expansion Cabinet
Base Cabinet
10A Fuse
PBTC-3M Cables (9 ft)
12 Volt4
Batteries
80 AMP/
HR Each
12 Volt4
Batteries
80 AMP/
HR Each
+
+
–
–
BATT
PSU
RBDB2
RBTC1A-2M2
Cable (6.5 ft)
–
+
–
+
–
+
–
+
“C” Cable
“C” Cables
Fuses
(10 AMP)
3 cables for
7 cabinets only
3 cables for
7 cabinets only
RBDB2
(cover
removed)
1477
RBTC1A-1.5M Cables (6-max)
Cable for 7th cabinet
(order number RC7C1A-1.7M)
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...